2.5.5 Profile specific GSD file: PA039742.GSD
The functionality of the profile specific GSD file is limited. This GSD file includes only four blocks:
The device has to be switched from full functionality (manufacturer specific) to interchangeable
basic configuration (profile specific) by using both a master class 2 tool or the device display
menu (IDENT_NUMBER_SELECTOR: Slot 0, Index 40; change byte value to 0). In the next step,
the device has to be configured using the PA039742.GSD file.
Block
number
Standard configuration
Function block output value
PA039742.GSD
Ident-No. 9742
Default
unit
1
Mass Flow
AI-FB
kg/s
2
Density
AI-FB
kg/m
3
3
Medium Temperature
AI-FB
K
4
Mass Totaliser
Totaliser-FB
kg