KROHNE Summit 8800 Vol 2 User Manual

Page 81

Advertising
background image

81

www.krohne.com

08/2013 - MA SUMMIT 8800 Vol2 R02 en

SUMMIT 8800

STREAM CONFIGURATION

06

6 .2 .3 .1 General

Figure 73 Differential pressure General section

Used Transmitters

This is the range of the transmitters to be used in the flow measurement. If

only one DP transmitter is to be used select Hi Range. If two or three ranges

are selected, the user will be prompted with switching values and new items

appear in the list left: Mid (2 or 3 ranges) and Low (if 3 ranges are selected0.

Switch up & down

This selection is defined as a percentage of the transmitters range, and

it’s instructions to switch up or down to the next transmitter. Based on the

percentage value of the range, the mid DP transmitter maybe required at a

user entered value to switch up to the high range transmitter or switch down

to the low range transmitter.

Measurement type

Select the restriction used in the pipe to create the differential pressure.

Pipe Constants
Dt0

The measurement of the pipe diameter at the reference temperature

t0D

The pipe reference temperature of the device when measured

λD

Linear expansion coefficient of pipe based on material due to thermal changes

Flow Element Constants
dt0

The diameter of the orifice plate at reference temperature

t0d

The reference temperature at the time of the orifice measurement

λd

Linear expansion coefficient of the orifice plate material due to thermal

changes

Dynamic Viscosity

Identify the source of viscosity measurement for the fluid. A choice of:
Keypad

Fixed user defined value

Sutherland (pressure)

Deriving the dynamic viscosity of fluid as the result of flowing pressure

Polynomial

Defining viscosity formulation as a function of temperature

Sutherland

The dynamic viscosity as the function of temperature using Sutherlands’s law

Keypad

The fixed keypad value

C

Sutherland constant

μ0

Viscosity at reference value of fluid

K11-K13

Viscosity constants

Advertising