KROHNE ALTOSONIC V Modbus EN User Manual

Page 41

Advertising
background image

ALTOSONIC V

ModBus Manual 0300 rev07 E

7.30855.35.00

Page 41 of 64

34

67

F32+R

Krohne use only

35

69

F32+R

Krohne use only

36

71

F32+R

Krohne use only

37

73

F32+R

Krohne use only

38

75

F32+R

Remaining hold time on real-profile sampling. By flow deviation

5

1

s

39

77

F32+R

Average by stdev: raw UFCdata Flow channel 1

5

1

0 to 1000

40

79

F32+R

Average by stdev: raw UFCdata Flow channel 2

5

1

0 to 1000

41

81

F32+R

Average by stdev: raw UFCdata Flow channel 3

5

1

0 to 1000

42

83

F32+R

Average by stdev: raw UFCdata Flow channel 4

5

1

0 to 1000

43

85

F32+R

Average by stdev: raw UFCdata Flow channel 5

5

1

0 to 1000

44

87

F32+R

Viscosity external (default not used)

1

cSt or 10-6 m2/s

45

89

F32+R

Temperature densitometer

2

°C

46

91

F32+R

Pressure densitometer

2

bar

47

93

F32+R

Temperature proving (external flowmeter)

8

°C

48

95

F32+R

Pressure proving (external flowmeter)

8

bar

49

97

F32+R

stdev: raw UFCdata Flow channel 1

5

1

%'

50

99

F32+R

stdev: raw UFCdata Flow channel 2

5

1

%'

51

101

F32+R

stdev: raw UFCdata Flow channel 3

5

1

%'

52

103

F32+R

stdev: raw UFCdata Flow channel 4

5

1

%'

53

105

F32+R

stdev: raw UFCdata Flow channel 5

5

1

%'

54

107

F32+R

Standard deviation of flow

5

1

%'

55

109

F32+R

Max deviation on tau2::tau2/10 for correction path 1

5

1

%'

56

111

F32+R

Max deviation on tau2::tau2/10 for correction path 2

5

1

%'

57

113

F32+R

Max deviation on tau2::tau2/10 for correction path 3

5

1

%'

58

115

F32+R

Max deviation on tau2::tau2/10 for correction path 4

5

1

%'

59

117

F32+R

Max deviation on tau2::tau2/10 for correction path 5

5

1

%'

60

119

F32+R

Max deviation on tau2::tau2/10 for correction flow

5

1

%'

61

121

F32+R

Max deviation on treal::treal/10 for profile measure path 1

5

1

%'

62

123

F32+R

Max deviation on treal::treal/10 for profile measure path 2

5

1

%'

63

125

F32+R

Max deviation on treal::treal/10 for profile measure path 3

5

1

%'

64

127

F32+R

Max deviation on treal::treal/10 for profile measure path 4

5

1

%'

65

129

F32+R

Max deviation on treal::treal/10 for profile measure path 5

5

1

%'

66

131

F32+R

Max deviation on treal::treal/10 for profile measure

5

1

%'

67

133

F32+R

Density densitometer

2

kg/m3

68

135

F32+R

Maximum flow rate

7

m3/h

69

137

F32+R

Ctl (15°C to process)

2

[ ]

70

139

F32+R

Cpl (0 bar to process)

2

[ ]

71

141

F32+R

Ctl (15°C to standard)

2

[ ]

72

143

F32+R

Cpl (0 bar to standard. always 1)

2

[ ]

73

145

F32+R

Ctl (15°C to densitometer)

2

[ ]

74

147

F32+R

Cpl (0 bar to densitometer)

2

[ ]

75

149

F32+R

Ctl (15°C to proving external flowmeter)

2

[ ]

76

151

F32+R

Cpl (0 bar to proving external flowmeter)

2

[ ]

77

153

F32+R

Batch 1 average temperature body

4

1

°C

78

155

F32+R

Batch 1 average temperature process

4

2

°C

79

157

F32+R

Batch 1 average temperature proving (external flowmeter)

4

8

°C

80

159

F32+R

Batch 1 average temperature densitometer

4

2

°C

81

161

F32+R

Batch 1 average pressure process

4

1

2

bar

82

163

F32+R

Batch 1 average pressure proving (external flowmeter)

4

8

bar

83

165

F32+R

Batch 1 average pressure densitimeter

4

2

bar

84

167

F32+R

Batch 1 average density densitometer

4

2

kg/m3

85

169

F32+R

Batch 1 average density standard

4

2

kg/m3

86

171

F32+R

Batch 1 avarage BS&W in percent

4

3

%

Advertising