ELECTRICAL CONNECTIONS

52

MFC 400

www.krohne.com

08/2013 - 4002075802 - MA MFC 400 R02 en

Pulse and frequency output passive P

N

NAMUR, Ex i I/Os

• Connection acc. to EN 60947-5-6
• open:

I

nom

= 0.43 mA

closed:
I

nom

= 4.5 mA

• X designates the connection terminals B or D, depending on the version of the signal

converter.

DANGER!
For devices used in hazardous areas, additional safety notes apply; please refer to the Ex
documentation.

INFORMATION!

Compact and field housing versions:

Compact and field housing versions:

Compact and field housing versions:

Compact and field housing versions: Shield connected via the cable terminals in the terminal
compartment.

Any connection polarity.

Figure 4-24: Pulse and frequency output passive P

N

as per NAMUR EN 60947-5-6 Exi