TECHNICAL DATA

8

43

BW25

www.krohne.com

09/2010 - 4000432302 MA BW25 R05 en

8.2 Technical data

INFORMATION!

The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local representative.

Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Download Center).

Measuring system

Application range

Level measurement

Operating method / measuring principle

Displacement principle

Measured value

Level, separating layer

Measuring accuracy

Standard

< 1.5% full scale value

Min. measuring range

0.3 m / 12"

Max. measuring range

6 m / 20 ft

Medium

Liquids

Density

≥ 0.45 kg/l / 28.1 lbs/ft

3

Materials

Housing

Aluminium with artificial resin coating

Housing option

Stainless steel (indicator M9)

Displacer rod

Stainless steel 1.4404

Displacer rod option

Titanium

Spring

Stainless steel 1.4571 (T

m

< 100°C / 212°F)

Spring option

ATS 340 (T

m

> 100°C / 212°F)

Flange

Stainless steel 1.4404

Pressure sleeve

Stainless steel 1.4404

Process connections

Max. operating pressure

40 bar - optional to 400 bar / 580 - optional 5802

psig

Standard flange

DN50 - PN40 / 2" ASME 300 lbs

Optional flange

...DN100 - ...PN400 / …4" ASME ...2.500 lbs

Approvals

ATEX, indicator M9 with electrical installations

Cat. II 1/2G, EEx ia IIC T6

ATEX, indicator M10

Cat. II 1/2G, EEx d IIC T6

ATEX, indicator M9 without electrical installations

for Zone 0 tanks

Cat. II 1/2 Gc

for Zone 1.21

Cat. II 2 GD

for Zone 2.22

Cat. II 3 GD