KYORITSU 1011 User Manual

Page 5

Advertising
background image

― 15 ―

● Standards

IEC61010-1 Measurement CAT.300V, pollution degree 2 / Measurement CAT.600V, pollution degree 2
IEC61010-031
IEC61326

● Mode of operation

△∑ mode

● Indication

LCD maximum value 6000 (ACV/A, DCV/A, Ω) / maximum value 9999 (Hz) / maximum valve 4000 (F), units, symbols

● Over range display

"OL" symbol is displayed on the LCD.
"OL" displayed when exceeding the measuring ranges. (except for AC/DC 600V ranges and AC/DC 10A ranges and Temperature
function.)

● Auto-ranging

Range shifts to upper range when indicated value is more than 6040.
Range shifts to lower range when indicated value is less than 560.

● Sampling rate

approx. 400ms

● Operating Environmental

−indoor use

conditions

−altitude up to 2000m

● Temperature & Humidity range

(guaranteed accuracy)

23℃±5℃

Relative humidity: less than 75%

● Operating Temperature &

Humidity range

0℃∼+40℃

Relative humidity: less than 80%

● Storage Temperature &

Humidity range

-20℃∼+60℃ Relative humidity: less than 90%

● Insulation Resistance

It should be more than 100MΩ/DC1000V between electrical circuit and enclosures.

● Withstand Voltage

It should be more than AC3700V/ for one minute between electrical circuit and enclosures.

● Overload Protection

Voltage function

:

720V (RMS.) 10seconds

Resistance function

:

600V (RMS.) 10seconds

Capacitance function

:

600V (RMS.) 10seconds

Frequency function

:

600V (RMS.) 10seconds

Temperature function

:

600V (RMS.) 10seconds

Current function : uA, mA

:

Protected by 600V 0.8A fuse

A

:

Protected by 600V 10A fuse

● Dimensions / Weight

approx. 161(L) x 82(W) x 50(D) mm / approx. 280g(including batteries, holster installation)

● Power source

Two R6P(AA)1.5V or equivalent

● Accessories

Test lead 1set / R6P (AA) 2p.c.s / Holster 1 / "K-Type" Temperature Probe 1 / Instruction manual 1

● Fuse

F600V/800mA (fast acting type), φ6.3 x 32mm / F600V/10A(fast acting type), φ6.3 x 32mm

CAUTION

● The voltage shown above is the overload protection(overvoltage protection)for the instrument. Make sure not to exceed the value of voltage shown above.
● In locations subject to radio frequency interference, the product may malfunction and it will recover automatically after the test.

−50∼0℃
−58∼32°

F

0∼150℃
32∼302°

F

150∼700℃
302∼1292°

F

±(5℃+5dgt)+accuracy of temperature probe
±(9°

F+5dgt)+accuracy of temperature probe

±(3℃+2dgt)+accuracy of temperature probe
±(5°

F+2dgt)+accuracy of temperature probe

±(2%+2dgt)+accuracy of temperature probe
±(2%+2dgt)+accuracy of temperature probe

Accuracy

°

C / °

F

Ranges

NiCr-NiSi sensor
If can not display bar graph on temperature

range

Overload protection: 600V DC or AC rms

Note

1℃/1°

F

Test condition