Replacement of safety discs – Lake Monitors WTA Hydraulic System Analyzer User Manual

Page 4

Advertising
background image

LAKE MONITORS reserves the right to make improvements and changes to the specification without notice.

Spacer

Disc

Disc holder

Safety Disc Cartridge

Disc

1. Remove safety disc cartridge with a 1-3/8" AF spanner.
2. Remove the internal disc holder in the cartridge with an 11/16" AF spanner.
3. Remove the two spent discs and fit new discs, one on each side of the spacer.
4. Tighten disc holder to 40 lb. ft. (55 Nm).
5. Check the seal before you replace the entire cartridge assembly in valve body.

N

S

Normal Flow

Direction

S

N

Pressure Control Valve

Safety Disc

Cartridge

2 Burst Discs

(Max. 6000 psi / 420 bar)

Spacer

Reverse

Flow

Direction

Replacement of Safety Discs

Normal Flow

Direction

Reverse

Flow

Direction

LAKE MONITORS INC.

2013 South 37th Street, Milwaukee, WI 53215

414.671.3577 / 800.850.6110 / Fax: 414.671.5253

www.lakemonitors.com

Division of Total Automated Solutions, Inc.

Advertising