Switches specifications, Electrical connections – Lake Monitors Flow Alarms User Manual

Page 4

Advertising
background image

Switches Specifications

Type

Form C, dry contact

UL/CSA Rating

10 & 1/4 hp, 125 or 250 VAC
1/2 A, 125 VDC & 1/4A, 250 VDC
3A, 125 VAC “L” lamp load

Mechanical Life

>10,000,000 cycles

Actuating Mechanical

Simulated roller, lever operated,
low force

Connectors

3/16" tab

Double Break Switch (Special)

Form Z - 10A &1/2hp,
125/250 VAC

Electrical Connections

Standard Flow Alarms
are pre-wired with 4-
pin Hirschmann-type
DIN connectors which
consist of a male
section as shown in
Illustration 4 and the
female section shown
in Illustration 5. To open the female section, first remove the screw,
then lift the connector portion out of the casing by inserting the head
of a screwdriver into the slot marked for that purpose. Illustration 6
shows the disassembled female section.

Page 4 / Flow Alarms / Lake Manual

Illustration 4

Illustration 6

Illustration 5

Advertising