Martel Electronics QM120ET User Manual

Qm 120 et, Nema 4 single hole mounting elapsed hour meter, Dimensions

Advertising
background image

DIMENSIONS

All dimensions in mm (inches)

FITTING THE Hour Meter

Drill a 5.5mm /

" hole in the panel. Fit seal to the rear of the module.

not overtighten the nut as this may damage the meter.

7

/

32

Fit the module to

the panel by passing its screw threaded stud and the wires through the hole, fitting the

washer and spring washer and tightening the nut provided. Take care not to trap any of

the connecting wires. Do

DO NOT PULL THE WIRES AND DO NOT ALLOW SCREW TERMINALS OR OTHER

WIRES TO HANG FROM THE MODULE'S WIRES, AS THIS MAY DAMAGE THE

PRODUCT.

QM 120ET is an easy to mount LCD digital elapsed hour meter. The module features 9999.9 and 99999 hour ranges, resulting in 1/10 hour and 1 hour resolution

respectively. A leading zero blanking input is provided, allowing the user to switch off unwanted leading zeros. The module incorporates an output which

pulses high after every hour counted. This is particularly useful in applications where maintenance or inspection are required at regular time intervals. The

timer features Trip and Total ranges. The Trip range can be reset to zero. To mount the unit into a panel, the user need only drill a single 5.5mm /

hole. The

module is fitted to the panel by locating its screw threaded stud through the hole, fitting the washer and tightening the nut provided. The module's 8

connecting wires pass through the hollow stud into the target application, where they can be easily connected as required. A rubber seal is included,

providing splashproof protection for the unit when fitted to the meter during installation.

"

7

/

32

Single Hole Mounting
9999.9 and 99999 Hour Ranges
9mm / 0.35" LCD Digit Height
Reset and Trip/Total Inputs
Leading Zero Blanking Input
Pulse Output Every Hour
Splashproof

QM 120 ET

Nema 4 Single Hole Mounting Elapsed Hour Meter

Shown Actual Size

REAR VIEW

CONNECTION

0

Black

0V

1

Brown

9999.9/99999

2

Red

V+

3

Orange

Voltage Sense

4

Yellow

1 Hr Pulse

5

Green

Leading Zero Blanking

6

Blue

Reset

7

Violet

Trip/Total

Washer

Elapsed

Hour Meter

Panel

8 Wires - 30cm (12.0)

Nut

21.4

0

(0.84)

10.70

(0.42)

5.00

(0.20)

10.70

(0.42)

43.50 (1.71)

LCD shown in power-on self-test mode.

21.75 (0.85)

21.75 (0.85)

SAFETY

To comply with the Low Voltage Directive (LVD 93/68/EEC), input voltages to the module’s wires must not exceed 60Vd.c. The user must

ensure that the incorporation of the meter into equipment conforms to the relevant sections of BS EN 61010 (Safety Requirements for

Electrical Equipment for Measuring, Control and Laboratory Use).

- - - - - - - - - -

- - - - - - - - - -

Stock Number

Easy Mounting Elapsed Hour Meter

QM 120 ET

Specification

Min.

Typ.

Max.

Unit

Resolution

Range 9999.9

0.1

Hour

Range 99999

1

Hour

Accuracy*

±2

±6

Sec./24Hrs.

Operating temperature range

0

50

°C

Supply voltage (V+)

5

27

V d.c.

Supply current

1.5

mA

Input Low Voltage (V **

0

0.5

V

Input High Voltage (V ***

2

V+

V

*

Based upon constant running. There is potential for ±2 seconds error each time

the module is powered down and then up again. Over time, the accumulated error

approximates to zero.

** Applies to the inputs: Range, V-Sense, LZB, Reset and Trip/Total

*** Applies to V-Sense input only.

IL)

IH)

- - - - - - - - - -

- - - - - - - - - -

Hrs

TRIP

TOTAL

Hrs

TRIP

TOTAL

Module thickness: 5.5mm (0.22")

9.0

(0.35)

Seal

Advertising