DIMENSIONS

All dimensions in mm (inches)

Required F.S.R.

Ra

Rb

2V

Note

910k

100k

20V

Note

1M

10k

200V

Note

1M

1k

2kV

Note

1M

100R

200 A

link

1k

2mA

link

100R

20mA

link

10R

200mA

link

1R

µ

15mm (0.6“) Digit Height
Programmable Decimal Points
Auto-zero
Auto-polarity
200mV d.c. Full Scale Reading (F.S.R.)
Single Rail Version

DPM 2000

3

½ Digit LCD Module

The DPM 2000 uses advanced components and construction techniques to provide an unrivalled combination of high performance,

elegant appearance and low cost. The module uses a bandgap reference for extra temperature stability. For single rail operation, the

DPM 2000S features a built-in negative rail generator, enabling the meter to measure a signal referenced to its own power supply 0V.

Specification

Min.

Typ.

Max.

Unit

Accuracy (overall error) *

0.05

0.1

% (±1 count)

Linearity

±1

count

Sample rate

3

samples/sec

Operating temperature range

0

50

°C

Temperature s

30

ppm/°C

Supply

DPM 2000

7.5

9

14

(V+ to V-)

DPM 2000S

3.5

5

6.5

V

Supply current

DPM 2000

150

DPM 2000S

500

A

Input leakage current (Vin = 0V)

1

10

pA

* To ensure maximum accuracy, re-calibrate periodically.

tability

voltage

µ

Stock Number

Standard Meter

DPM 2000

Single Rail Version

DPM 2000S

ON BOARD

SOLDER LINKS

SCALING RESISTORS

SCALING

NOTE

67.5 (2.66)

32.5

(1.28)

27.5

(1.08)

19.0

(0.75)

29.5

(1.16)

29.5

(1.16)

60.0 (2.36)

53.0 (2.09)
62.5 (2.46)

Ø2.50

(0.10)

c d e

f

g

TEST XB3

XDP -5V CLK XG3 V+ RBG REF

-

REF+

E3 BP AB POL REF

HI

REF

LO

COM L

H V-

I

I

+ -

pH

% V g °F °C A

m

M K

DP1 DP2 DP3

~

: -

µ

Display in TEST mode

a. 1.00 (0.04)

b. 9.00 (0.35)

c. 1.25 (0.05)

d. 5.50 (0.22)

e. 4.00 (0.16)

f. 0.50 (0.02)

g. 2.54 (0.10)

LMP

8

13

12

H5

9

6

14

11 4 2 7

5

1

3

10

Rb

Ra

Two resistors Ra and Rb may be fitted in order to alter

the full scale reading (F.S.R) of the meter - see table.

The meter will need re-calibration.

Ensure that link 10 is open if fitting Ra.

SAFETY

To comply with the Low Voltage Directive (LVD 93/68/EEC), input voltages to the module’s pins must not exceed 60Vdc. If voltages to the measuring

inputs do exceed 60Vdc, then fit scaling resistors externally to the module. The user must ensure that the incorporation of the DPM into the user’s

equipment conforms to the relevant sections of BS EN 61010 (Safety Requirements for Electrical Equipment for Measuring, Control and Laboratory Use).

72.0 (2.83)

36.0

(1.42)

a b

Advertising