FEATURES

ORDERING INFORMATION

Stock Number

Standard Data Logger

EL-USB-3

(Data Logger, Measurement Leads,
Software on CD and Battery)

Replacement Battery

BAT 3V6

• 0-30V d.c. Measurement Range
• Logging Rates between 1s and 12hr
• Stores 32,510 readings
• Connection via two screw terminals
• USB Interface for Set-up and Data Download
• User-Programmable Alarm Thresholds
• Red and Green LED Status Indication
• Replaceable Internal Lithium Battery

EL-USB-3

Voltage USB Data Logger

This data logger measures and stores up to 32,510 voltage readings over a 0-30V d.c. measurement range. The user can easily set up
the logging rate and start time, and download the stored data by plugging the module straight into a PC's USB port and running the
purpose designed software under Windows 98, 2000 or XP. The data can then be graphed, printed and exported to other
applications. The data logger is supplied complete with a long-life lithium battery. Correct functioning of the unit is indicated by
flashing red and green LED. The data logger features a pair of screw terminals and is is supplied complete with a set of measurement
leads terminating in crocodile clips.

WINDOWS CONTROL SOFTWARE

Easy to install and use, the control software runs under
Windows 98, 2000 and XP (Home and Professional
Editions). It allows the user to set up and download any EL-
USB-3. The latest version of the control software may be
downloaded from

.

www.lascarelectronics.com

DATA LOGGER SET-UPS

• Logger Name
• Logging Rate (1s, 10s, 1m, 5m, 30m, 1hr, 6hr, 12hr)
• High and Low Alarms
• Start Date and Start Time

SPECIFICATIONS

Specification

Min.

Typ.

Max.

Unit

0-30V d.c. measurement range

0

30

V d.c.

Internal resolution

50

mV d.c.

Accuracy (overall error)

1

%

Logging rate

every 1s

every 12hr

-

Operating temperature range

-25 (-13)

+80 (176)

°C (°F)

1/2AA 3.6V Lithium Battery Life*

1

Year

+

* depending on ambient temperature, logging rate and use of alarm LED.