Installation – Precision Control Systems CoolIR C100 User Manual

Page 5

Advertising
background image

Size C100 CoolIR
1. Determine heater(s) wattage

Example: E4-05 w/500 watt lamps
Wattage = 4 x 500 = 2000 watts

2. Determine cooling factor (Fc)

Model

Fc Description

E4 0.9

All

5193

0.9 Multiple 5193's facing each other

5193

0.7 5193(s) facing target > 800 ºC

5193

0.5 5193(s) facing target from 400 ºC to 800 ºC

5193

0.3 5193(s) facing target < 400 ºC

5305

0.9 Multiple 5305's facing each other

5305

0.6 5305(s) facing target > 800 ºC

5305

0.4 5305(s) facing target from 400 ºC to 800 ºC

5305

0.2 5305(s) facing target < 400 ºC


3. Calculate cooling load (Lc)

Lc = Heater wattage x Fc
Example: Lc = 2000 x 0.9 = 1800 watts

4. Determine number of C100's needed

C100 rating = 3300 watts
Lc = 1800 watts

1 - Model C100-1 required

Table 1 - C100 Heater/Cooler Sizing

Installation

1. Connect the water fittings to the cooling unit and the heater. Use Teflon tape thread

lubricant around the pipe thread fittings. Refer to the figures in the back of this
manual for installation with various heater configurations.

2. Connect water hoses to fittings marked "Water From Welding Equipment" and Water

To Welding Equipment". The “Welding Equipment” is the IR heater. Flow direction
through the heater does not matter.

Research, Inc. • USA • Ph: 952.949-9009 • Fax: 952.949-9559•

[email protected]

www.researchinc.com

5

Advertising