1. Safety: When installing and using this electrical equipment, basic safety precautions

should always be followed, including:

1.1 WARNING !: To reduce the risk of injury, do not permit children to use this product unless they are
closely supervised at all times


1.2 WARNING !:
Risk of electric shock.

Connect only to a grounding type receptacle protected by a ground-fault circuit interrupter (GFCI). Contact
qualified electrician if you can not verify that the receptacle is protected by a GFCI and that your installation
meets local electrical codes, including grounding of water system components.

1.3 WARNING !: Risk of electric shock.
Do not bury or modify the metering pump cord. Locate cord to minimize abuse from lawn mowers, hedge
trimmers, and other equipment

1.4 WARNING !:
Risk of electric shock.
On cord and plug connected units, replace a damaged cord immediately.

1.5 WARNING !:
Risk of electric shock.
Do not use extension cord to connect unit to electrical supply; provide a properly located outlet

1.6 WARNING !:
Risk of electric shock.
Do not install within an outer enclosure or beneath the skirt of a hot tub or sap unless so marked. All
instructions must be in accordance with appropriate electrical codes.

1.7 WARNING !: Risk of electric shock/pinching/chemical exposure.
Remove power sources or lockout circuit prior to performing maintenance on metering pump.
Pumps are usually timer controlled and can start at any time.

1.8 WARNING !
: Risk of Chemical Overdose/Exposure.
Removing power from circulating pump must also remove power from the chemical injection pump.
Provide a properly located outlet controlled by the circulating pump circuit.

1.9 WARNING !: Risk of Chemical Overdose/Exposure
Use a devise such as a flow switch to shut-off power from the from the chemical injection pump in the event of
pool pump or circulation failure.
It is not safe to automatically dispensed chemicals into a circulating system that is not running.

1.10 WARNING !: Risk of Chemical Overdose/Exposure
Minimize amount of chemical on site that is available to dispense.
Size the feeder and container to pool/spa capacity.
Dilute chemical for small bodies of water.

1.11 WARNING !: Risk of Chemical Exposure
De-pressurize the system prior to connecting or disconnecting the metering pump.

1.12 CAUTION ! :Wear protective clothing, gloves and safety glasses at all times when working on or near the
metering pump.

1.13 CAUTION !
:Install the metering pump and chemical containers in a ventilated secured location. Protect
children, pets, and property from chemical hazards. Containment and/or wash down capability must be in
accordance with local regulations and chemical suppliers’ instructions.

1.14 CAUTION !:
Read and follow all instructions supplied with the chemical being fed. User is responsible for
determining the compatibility of the chemical with the metering pump.
Consult supplier of chemical if use and handling instructions are not available.