2.2 Specifications

Parameter

Display

Control Factory Default .

pH:

6.8 to 8.4

7.0 to 8.0

7.4

ORP:

0 to 995 mV

ORP1: (5 mv increments)

400 mV to 900 mV 650mV

ORP1: (5 mv increments)

400 mV to 890 mV 640mV


Input Power
120 Volts AC, 50/60 HZ, 3 wire grounded power cord.

Combined load not to exceed 15 amps.

GFCI source required

Output Power

120 Volts AC, 50/60 HZ, ORP1, OPR2 and pH , 5 amps each (fused)

Two 3-wire grounded power receptacles

Terminal strip for hardwire applications (included)


Displays:

ORP and pH – red digital
Power and flow indicator – LED (blue/green)
Alert indicator & Feed indicator- LED (pH, ORP1& OPR2)
Mode indicator- LED (pH ,ORP1, ORP2 , Auto)


NOTE- feed lamps flash during the feed time and are on constant during the delay time of the
feed cycle.

O

perating Temperature: 40 to 120° F


Selectable Features
+ ORP1& ORP2 settings

+pH settings

+ Manual feed (Feed Once)

+ ORP1& ORP2 feed/delay times + pH feed/delay times + pH calibration
+High & low ORP and pH alerts + Reset
+ Acid/base feed

+ Keypad Lockout

+ Adjustable time-out

+ ORP and pH Interlock


Features and Options
+ Flow switch input

+ Individually fused outputs + 120 vac transformer





Rola-Chem Digital Controller PN 554331 6/01/2012 Page: 6 of 20