4 typical system installations – Rola-Chem RC554XP ORP/pH Digital Controller User Manual

Page 18

Advertising
background image

Rola-Chem Digital Controller PN 554135 02/17/2014 Page: 18 of 20

8.4 Typical System Installations

**SAFETY FLOWSWITCH TO ENSURE
CIRCULATION TO CONTROL PROBES
AND INDICATOR THAT POOL
CIRCULATION IS OCCURRING.

CONTROLLER

FILTER

TYPICAL SODIUM HYPOCHLORITE FEED SYSTEM

POOL
PUMP

*SAFETY FLOWSWITCH FOR

PROTECTION OF HEATER AND

TO ENSURE DILUTION OF
CHEMICAL INTO POOL.

WATER

FROM
POOL

BASKET

CHLORINE
PUMP

CHLORINE
NaOCl

***FILTER

ELECTRICAL OUTLET
CONTROLLED BY
CIRCULATION SYSTEM

*** OPTIONAL FILTER TO

HELP KEEP MANIFOLD

AND PROBES CLEAR OF

DEBRIS.

*FLOWSWITCH

EARTH
GROUND

WATER
TO

POOL

ACID

PUMP

HEATER

ACID

HCl

MANIFOLD

**FLOWSWITCH

EARTH
GROUND

WATER

FROM
POOL

WATER
TO

POOL

EARTH
GROUND

SYSTEM USING EROSION FEEDER (TRI-CHLOR/ DI-CHLOR) WITH SODA ASH PUMP

**SAFETY FLOWSWITCH TO ENSURE
CIRCULATION TO CONTROL PROBES

AND INDICATOR THAT POOL

CIRCULATION IS OCCURRING.

*SAFETY FLOWSWITCH FOR

PROTECTION OF HEATER AND

TO ENSURE DILUTION OF
CHEMICAL INTO POOL.

*** OPTIONAL FILTER TO

HELP KEEP MANIFOLD

AND PROBES CLEAR OF

DEBRIS.

POOL
PUMP

FILTER

***FILTER

CONTROLLER

HEATER

*FLOWSWITCH

CHECK

VALVE

EROSION
FEEDER

SODA

ASH

MIXER

pH
SOLUTION

pH PUMP

TIMED FEED

STRAINER

SOL. VALVE
(120 V.)

MANIFOLD

**FLOWSWITCH

ELECTRICAL
OUTLET
CONTROLLED BY
CIRCULATION

SYSTEM

Advertising