EM100/102 LOW FLOW

MAGNETIC FLOW METER

INSTRUCTIONS

1- 800 -975 - 8153

EM 100/102

LOW-FLOW MAGNETIC FLOW METER

INSTRUCTIONS

EM 100/102 - 025
EM 100/102 - 038
EM 100/102 - 050

GENERAL INFORMATION

FLOW RANGE

SPECIFICATIONS

M AT E R I A L S

Wetted Materials -

Body: Kynar™ PVDF

Electrodes: Platinum over titanium

Internal Seals: Viton™

Housing -

ABS

P O W E R

12-24 VDC, 180 mA

A C C U R A C Y

+/-1% of reading, above 10% of full scale

+/-3% of reading, below 10% of full scale

M A X I M U M F L U I D T E M P E R AT U R E

185º F

M A X I M U M P R E S S U R E

150 PSI (@ 75º F)

M I N I M U M C O N D U C T I V I T Y

20 microsiemens

O U T P U T S

Frequency opto isolated 1000 pulse/liter (3785 p/g)

Optional 4-20 mA opto isolated passive

The EM100 is a 24 VDC-powered electromagnetic flow meter with

chemically-resistant plastic wetted parts, in nominal maximum flow rates of

4, 11, and 30 liters per minute. It uses bipolar DC technology at a frequency

high enough to allow for measurement of pulsating flows from diaphragm-

type chemical metering pumps. All electronics are contained in a single

compact, chemical-resistant housing. This configuration, combined with the

standard pulse and analog outputs, makes the EM100 well suited for OEM

applications. Other applications include remote monitoring of chemical

volume or rate using a computer or PLC.

SIZE

NOMINAL FULL SCALE

MIN. FOR 1% ACCURACY

LOW FLOW CUTOFF

L/MIN.

GAL./MIN.

GAL./HR.

L/MIN.

GAL./MIN.

GAL./HR.

L/MIN.

GAL./MIN.

GAL./HR

-025

3.8

1

60

.38

0.1

6

.04

.009

.54

-038

11

3

180

1.1

.3

18

0.1

.025

1.5

-050

30

8

480

3.0

.8

48

.25

.065

3.9