Seametrics EM 101 v.1 User Manual

Ar ch ive d, Includes dates before 1 1/06), E m 1 0 1

Advertising
background image

1- 800 -975 - 8153

E M 1 0 1

LOW-FLOW MAGNETIC FLOW METER

INSTRUCTIONS

EM 101-025
EM 101-038
EM 101-050

GENERAL INFORMATION

SIZE

NOMINAL FULL SCALE

MIN. FOR 1% ACCURACY

LOW FLOW CUTOFF

L/MIN.

GAL./MIN.

GAL./HR.

L/MIN.

GAL./MIN.

GAL./HR.

L/MIN.

GAL./MIN.

GAL./HR

-025

3.8

1

60

.38

0.1

6

.04

.009

.54

-038

11

3

180

1.1

.3

18

0.1

.025

1.5

-050

30

8

480

3.0

.8

48

.25

.065

3.9

FLOW RANGE

SPECIFICATIONS

M AT E R I A L S

Wetted Materials -

Body: Kynar™ PVDF

Electrodes: Platinium coated titanium

Internal Seals: Viton™

Housings -

Primary Element: Fusion coated aluminum

Control / Display: Polycarbonate

P O W E R

115 VAC, 60 Hz, optional 220 VAC/50Hz

A C C U R A C Y

+/-1% of reading, above 10% of full scale

+/-3% of reading, below 10% of full scale

M A X I M U M F L U I D T E M P E R AT U R E

185º F

M A X I M U M P R E S S U R E

150 PSI (@ 75º F)

M I N I M U M C O N D U C T I V I T Y

20 micro Siemens

O U T P U T S

4-20 mA, 0-5 Volts (both isolated)

Frequency to 9999 pulses per gallon, Isolated 10 mA, 30 VDC

High alarm, low alarm relay, Isolated

(100 mA, 110 VAC/VDC)

The EM101 is a small plastic-bodied electromagnetic flow meter,

in nominal maximum flow rates of 1, 3, and 8 gpm. Capable of measur-

ing the pulsating flows from air and solenoid-driven metering pumps,

the meter is primarily designed for electrically-conductive chemicals. In

addition to measuring and displaying flow rate and total flow, this unit

has a variety of outputs. For continuous transmission of a flow signal,

there is a 4-20 mA, and 0-5 Volt signal, and a frequency signal propor-

tional to flow. In addition, there are relay alarm outputs for low and

high flow with user-set flow levels.