Seametrics FS30 User Manual

Disc ont inue d

Advertising
background image

LT-10524-A

1 of 4

General Information

The FS30 is designed for use with any SeaMetrics flow
meter or flow sensor to activate a switch closure at a set
flow rate. Particularly suited for critical flows, it is called
an “active” flow switch because if it should fail it would
tend to fail in a false “no flow” condition, unlike vane-type
switches which easily fail in a false “flow” mode. The FS30
can be set to activate on rise or fall, and the set point is
input using rotary digital switches.

A variable hysteresis or deadband setting is provided to
accommodate varying amounts of turbulence in the flow
metering application. If the turbulence is significant, a
larger deadband keeps the switch from chattering on and
off when the flow is very close to the setpoint.

Specifications

Power

12 - 36 VDC

Flow Sensor Power

5 VDC, 20 mA

Output

Form C relay, 10 A
@ 120 VAC or 28 VDC max

Setting Range

1 - 999 Hz

Accuracy

1 %

Hysteresis

1 - 10%

Modes

High (close on rise),
low (close on fall)

Response Speed Switch (after 90% change)

Change rising

2.0 second

Change falling

3.0 second

Indicators

Power on (green), switch (red)

Temperature

32º- 120ºF (0º- 5ºC)

FS30 Active Flow Switch
Instructions

DISC

ONT

INUE

D

(12/31/06)

Advertising