Seametrics FT420-98 User Manual

Ar ch ive d

Advertising
background image

FT420 Relay Output
Instructions

-

12-30 VDC

Red
White

Black

TX81

Flow Sensor

white
wire

red
wire

Device one

Device two

30221

+

+

+

-

-

Installation

Please note that if you purchase the FT420 with
option 98, the required component will come
preinstalled, and no extra procedures are required. If
you are retrofitting an existing installation of an FT420
with the relay board, please follow the instructions
below.

Peel the backing off of the double-stick tape and affix
it to the bottom of the relay board (part number
30221). Carefully attach the board to the FT420 as
shown in the diagram below. Be sure that the red wire
faces the “Sensor Input” side of the FT420, and that
the white wire faces the “Pulse Output” side. Connect
the white wire to the “Pulse Scaled” positive terminal,
and the red wire to the “Power 4-20mA” positive
terminal. Connect devices to the relays as desired

.

Specifications

Input Voltage:

7-30 VDC

Output Current (both outputs):

Input Voltage

50 C

85C

12VDC

120mA

70mA

24VDC

120mA`

80mA

Max Pulses/Second:

5

Contact Time Per Output: 100 ms

AR

CH

IVE

D

Advertising