Turn Power-ON

Display

Push

key — Press shift and increment keys simultaneously for at least 3 sec.

Now the decimal point can be selected.

dp

— Press increment key and set the decimal point.

Push

key

— Press key. Now you can select RPM or linear speed.

diS-t

— Press increment key and select "r-t" or "L-t".

Push

key

— If "L-t" is selected. Now "units" can be chosen.

Unit

— Press shift and increment keys

and select "M/min", "Ft/min" or "Y/min".

Push

key

— Now you are in the PPr field.

PPr

— Press shift key and increment key and select the number of PPr anywhere from 1 to 9999.

Push

key

— You are in the minimum RPM/Linear rate field. (minimum speed)

LS-t

— Press shift key and increment key and select cut-off sampling time

anywhere from 0.1 to 99.9 sec. Factory setting is 3 sec.

Push

key

— You are now in the speed stability field.

Aug

— Press shift key and increment key and set value between 1 and 99

depending how fast speed changes.

Push

key

— Press shift and increment keys (simultaneously) momentarily and start measuring

or push key and start cycle all over again.