7. Verification Steps

The following steps can be used to verify and/or troubleshoot installations in the field.

1. Verify that the staus of the loop start trunk connected to the 3226 Trunk Port FXO

Doorphone is in-service using the status trunk command on Communication Manager.
Below is the output of the command.

status trunk 100

TRUNK GROUP STATUS

Member Port Service State Mtce Connected Ports
Busy

0100/001 001V208 in-service/idle no

2. Verify that when the call button on the Door Station is pressed, the specified telephone on

Communication Manager rings, and upon answering the call, two-way audio path is
established.


3. Verify that the 3226 Trunk Port FXO Doorphone returns to the idle state when the call is

terminated.


4. Verify that incoming calls to the 3226 Trunk Port FXO Doorphone are also successful.

8. Conclusion

These Application Notes describe the administration steps required to integrate the Algo 3226
Trunk Port FXO Doorphone with Avaya Aura® Communication Manager. Calls to the 3226
Trunk Port FXO Doorphone were successful in both directions. In addition, unlocking a door
using DTMF tones was successful. All test cases passed.

9. Additional References

This section references documentation relevant to these Application Notes. The following Avaya
product documentation is available at

http://support.avaya.com

.


[1] Administering Avaya Aura

TM

Communication Manager, June 2010, Release 6.0, Issue 6.0,

Document Number 03-300509.


The following Algo product documentation is available at

http://www.algosolutions.com

.


[2] Algo 3226 Trunk Port FXO Doorphone Installation and User Guide, Document Number 90-

00040A.