Advanced Protection S50A User Manual

Page 4

Advertising
background image

Page 4

Normal Operation

Green LED Indicator

The LED indicator illuminates when the SPD is energized

and operating correctly. Indicator operation: Every

suppression element is connected via logic to the green

LED. Should any suppression element fail, the green LED

will extinguish.

Maintenance

SPDs require minimal maintenance. We recommend

periodic inspection of diagnostic indicators to ensure

proper operation. We also recommend keeping the SPD

clean as appropriate.

Troubleshooting & Service

Please contact us for any service related issues. We want

to take care of any problems.

Quality SPDs withstand severe duty and attempt to

protect their load until failure. There are electrical

anomalies that SPDs cannot protect against. These

are generally Sustained Overvoltages also known as

Temporary Overvoltages (TOVs). In this context, Sustained

Overvoltages may be only a few cycles. Failed SPDs tend

to be symptoms, not root causes. We suggest treating a

failed SPD as a ‘canary in the coalmine’ as there may be

larger issues at play. As a generalization, the single largest

‘killer’ of SPDs is reference to ground issues. If the SPD

3.26”

3.26”

1.15”

4.13”

3/4”-14

Sized for std 35mm DIN-rail

3.31” 3.57”

Weight: 1.60 lbs

(0.73 kg)

Figure 3

Bracket Mount

for flat surfaces

Std. 3/4”-14 Nipple

DIN-rail Mount

(rail not incl.)

Figure 4

• 3/4” pipe nipple (conduit nut included)

• Standard 35mm DIN-rail (not included)

L-bracket tightens onto DIN-rail (available

upon request)

• Standard flat mounting surface

Attach L-bracket to surface via mounting holes

S50A Mounting Options

Dimensions and Weight

surge

assure

TM

14550 58th Street North Clearwater, Florida 33760

1.800.727.0669 - [email protected] - www.surgeassure.com

A Division of Advanced Protection Technologies, Inc.

APT’s Quality Management System is ISO 9001:2000 Certified

shows problems on startup, there is reasonable chance of

bonding/grounding/misapplication issue. This permanently

damages the unit. If not corrected, it will happen again.

Limited Warranty

surge

assure

TM

warrants it’s AC electrical distribution

equipment protection products against defective work-

manship and materials for 10 years. Liability is limited to

the replacement of the defective product. A Return Ma-

terial Authorization number (RMA #) must be given by

the company prior to the return of any product. Returned

products must be sent to the factory with the transporta-

tion charges prepaid.

The company specifically disclaims all other warranties,

expressed or implied. Additionally, the company will

not be responsible for incidental or consequential

damages resulting from any defect in any product or

component thereof.

Technical Support and Customer Service

1.800.727.0669 · [email protected]

This manual as well as information about the entire

surge

assure

TM

product line are available on the Internet

at: www.surgeassure.com.

Prior to calling

surge

assure

TM

for technical support,

please have the following information available:

Model Number of unit: _________________________
Manufacture Date:

_________________________

Purchase Date:

_________________________

Your Order Number:

_________________________

Return Shipment Address:

surge

assure

TM

14550 58th Street North

Clearwater, FL 33760

Attn: RMA#______________________

rB06.11.12.rs #8221