Accessories, Tme low temperature cut-out thermostat, Change-over ch 15-25 – Airedale Chilled Water Cassette 2kW - 11kW User Manual

Page 18: Fresh air connection, Fresh air kit, Units with remote electric board

Advertising
background image

19

Technical Manual:

6806236 0

/20

CHILLED WATER CASSETTE

Identification

Code

CAP

6078005

Identification

Code

CH 15-25

9053049

Identification

Code

TME

3021091

m

3

/h

Pa

160
200
300
400
500

3
8

15
25
36

TL 4-5-6

m

3

/h

Pa

80

120
160
200
240

3
8

15
25
36

TL 0-1-2-3

Correlation between

flow-rate / static pressure

RED

BLACK

PRT 800

9079231

TL 4-5-6

Identification

Code

PRT 600

9079230

Model

TL 0-1-2-3

TME low temperature cut-out thermostat

Suitable for wall controls only (not infra-red remote control). To be fitted between the coil fins;
when connecting the control, the TME probe cable must be separated from the power supply wires.
To be used with the following controls: TMO-T, TMO-T-AU, TMO-DI.

The fan stops when the water temperature is lower than 38°C
and it starts the fan when it is higher than 42°C.

Change-Over CH 15-25

Suitable for wall controls only (not for infra-red remote control).
Automatic summer/winter switch to be installed
in contact with the water circuit (for 2-tube installations only).
To be used with the following controls:
TMO-T, TMO-T-AU, TMO-DI.

Fresh air connection

See page 13.

Fresh air kit

This is used to introduce primary air into the environment directly through the
diffuser. The kit includes a flow separator to be fitted inside the cassette, and
a circular fitting for connection to the flexible system ducting. The flow of air is
sent directly to just one of the outlet louvers, without passing through the coil.
The air flow of fresh air introduced into the environment depend on the inlet
static pressure.

The diameter of the fitting

is 150 mm for TL 0 - 1 - 2 - 3

and 180 mm for TL 4 - 5 - 6.

Units with remote electric board

On request the Airedale cassettes are available with electric control panel reachable from below and with the electric
board that can be placed in a remote position. In this case the units are supplied with an electronic connecting control
panel, fitted to the bottom side on the 4 smallest sizes and to the
lateral side on the 3 biggest sizes.
The electronic control panel is connected to the fan motor, to the
condensate pump and to the condensate level control. A 6 m wire
is also supplied with integral plug-in connections to connect the unit
with the remote electric board that can be installed in a suitable and
comfortable position, where the power and system connections can
be made easily.
This feature is not available for units with electric resistance or infra-
red remote control.

Accessories