American Standard Whirlpool/Bathing Pool 2675 Series User Manual

Installation instructions, Whirlpool/bathing pool, 2675 series

Advertising
background image

INSTALLATION INSTRUCTIONS

T H A N K Y O U . . .

for selecting an American Standard bath. Your new
bath is shipped to you after careful inspection. The
whirlpool version is completely assembled with pump,
motor, and system piping. All you need to finish the
installation are your selected fittings and electrical
connections for a whirlpool.

To insure maximum performance and pleasure from
this product, please follow the instructions and
cautions.

GENERAL INSTALLATION INFORMATION

Carefully uncrate, peel-out protective film and
inspect your new bath for any shipping damage. If
such damage is found, report it to your vendor
immediately.

After inspection and during installation, protect the bath
from construction damage. After installation, and before
enclosing with wallboard, tile, etc., water test the unit
and check for leaks.

If a whirlpool, do not make modifications to the whirlpool
system or remove pump from factory mounting. This
could adversely affect the safety and performance of the
whirlpool and void the warranty. Do not handle or move
the whirlpool by the pump, motor, or piping system.

Fittings (bath filler, shower arm, etc.) are not provided
with the bath and must be ordered separately. Framing
and enclosing materials are provided by others. Check
for availability of optional American Standard wall tiling
bead (required for recess installations).

Protect all finished surfaces of the whirlpool during
construction and installation using a drop cloth.

WARNING! Do not lift whirlpool by the piping har-
ness at any time.

NOTE: Deck-mounted fittings are not recommended.

752445-100 Rev. E

© American Standard Inc. 2003
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.

HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS

COLONY™ 5'

WHIRLPOOL/BATHING POOL

List of Optional Components (not included):
• Tile Bead Kit 751755-100*
• Apron Kit*

List of Required Components (not included):
• Drain 1583.470* • Bath Filler*
* see your American Standard Distributor

List of Required Tools and Supplies:

Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun

Supplies
• Nails
• Putty
• Caulking (waterproof)
• 2 x 3 or 2 x 4
Stringers
• Drop Cloth
• 15 amp GFI
Outlet
• Cement, Plaster,
Grout

FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.

60 x 32-3/4 x 19-3/4 In.(1524 x832 x 502mm)

95 Lbs. (43 Kg.)

604 Lbs. (275 Kg.)

61 Gal. (230 L.)
42 Gal. (159 L.)

20 x 39 In. (508 x 991mm)

27-1/2 x 56 In.(699 x 1422mm)

14-1/4 In. (362mm)

44 Lbs./Sq. Ft. (213 Kgs/Sq. m.)

15.6
29.6

GENERAL SPECIFICATIONS FOR 2675 WHIRLPOOL

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT

3

)

WHIRLPOOL ELECTRICAL SPECIFICATIONS

1.1 HP, 9.9 AMPS, 120V.

PUMP

464 mm

(18-1/4)

38 mm

(1-1/2)

502 mm

(19-3/4)

1-1/2 O.D.TAILPIECE

BATH

SUPPORT

MATERIAL

LEVELING STRINGER

NOT FOR SUPPORT

ROUGH

FLOOR

1524 mm

(60)

832 mm

(32-3/4)

OUTLINE OF CUTOUT
1486 mm x 794 mm
(58-1/2 X 31-1/4 )

416 mm

(16-3/8)

216 mm

(8-1/2)

305 mm

(12)

38 mm

(1-1/2)

(6) JETS

79 mm

(3-1/8)

CUTOUT IN FLOOR FOR DRAIN

PUMP

FINISHED

WALL

305 mm

(12)

OPTIONAL TO

FINISHED FLOOR

USUALLY BETWEEN

1651 & 1981mm

(65 & 78)

C/L OF
OVERFLOW

102 mm

(4)

C/L OF
SPOUT

C/L OF
VALVES

C/L OF
SHOWER ARM

70 mm

(2-3/4)

117 mm

(4-5/8)

1-1/2 N.P.T.M.

THREADS

19 mm

(3/4)

229 mm

(9)

C/L OF

SUPPLIES

SEE FITTING

SPECS FOR

DIMENSIONS

(1) AIR VALVE

ON/OFF
SWITCH

PROVIDE ACCESS TO PUMP FOR

SERVICING ON ALL INSTALLATIONS

2675 SERIES

Advertising