ULTRASONIC METER PRE-INSTALLATION

• Inspect the piping around the meter setting for suitable

conditions. The service line, valves, connections and meter must

be watertight. Repair the piping system if corroded or damaged.

• Set the meter in a horizontal or vertical position with flow in the

up direction. Registration should be upright and protected from

damage, freezing, and tampering.

• Position the meter so it is accessible for installation, removal

and reading.

• Verify that a suitable, electrical grounding wire is properly

attached to the upstream and downstream pipe connections

of the meter. The grounding wire provides an alternative path

for any electrical current that may exist across the opening in

the line.

• Close the curb (shutoff) valve to relieve water pressure in the

line before starting the cutting operation. Provide a high-quality

upstream shutoff valve with a low pressure drop.

• When cutting into a new section of service pipe, flush the pipe

to clear chips, pipe dope or other plumbing residue.

• For 5/8" to 1" meters, the line opening in which the meter is

to be set should match the laying length of the meter, allowing

slight additional space for coupling gaskets. The inlet and outlet

sides of the meter should be set axially aligned to the pipe.

• For 1-1/2" and 2" meters, the line opening in which the meter

is to be set should match the laying length of the meter. For

optimal performance and accuracy, it is also recommended that

five to ten diameters of straight pipe be installed upstream of

the meter.

• The installed meter must not be an obstacle or a hazard to the

customer or interfere with public safety.

• During meter installation, you may choose to replace the old

gaskets with the provided 9/64" thick rubber gaskets.

Storage Mode

All E-Series Ultrasonic meters are delivered in a storage mode

so that a meter alarm is not triggered. During storage mode, the

empty pipe shows up on the LCD display as an error message, but

it will not trigger a meter alarm. The meter needs to sense a full

pipe for 24 hours for the meter to go from storage mode to normal

operation. If installed when the meter is still in storage mode, the

meter will function as expected with the addition of also displaying

“err” on the flow rate screen. The meter will display consumption

and, if connected to AMR/AMI, will send a reading to the endpoint.

When the meter is in normal operation, the meter alarm displays

immediately upon detecting the empty pipe condition. The alarm

clears immediately after the condition is corrected and the pipe is

full. Systems that support the additional alarm conditions will be

notified that an empty pipe condition has occurred.

Status Indicators

Other indicators and alarms appear in the display as symbols that

illuminate when the condition is active and dim when the alarm

condition is eliminated. For additional status indicator information,

refer to the Installation and Operation manuals, available online at

www.badgermeter.com

.