Assemble the orion endpoint and gas meter index, Endpoint and lens gasket attachment, Assemble the orion endpoint and gas meter index 9 – Badger Meter ORION AMR/AMI Hardware Solutions for Gas Utilities User Manual

Page 9: Endpoint and lens gasket attachment 9

Advertising
background image

Installation Manual

ASSEMBLE THE ORION ENDPOINT AND GAS METER INDEX

Endpoint and Lens Gasket Attachment

These gaskets should be attached to the endpoint at the factory If the gaskets are not attached:
1 Place the endpoint gasket on the back of the endpoint See

Figure 7

and

Figure 8

a Place the thin part of the gasket at the top of the endpoint and the tines through the small holes in the endpoint

Thin part of gasket

Gasket tines into holes

Figure 7: Placement of gasket

b Place the drain slots and rib facing outward

Rib

Drain slots

Figure 8: Drain slots and rib facing outward

2 Place the protruding four tines in the four small holes in the endpoint Pull the tines snuggly through the holes with a

needle nose pliers See

Figure 9

Figure 9: Pull tines through holes

Page 9

July 2014

Advertising
This manual is related to the following products: