APPENDIX: EXAMPLES OF INDEX VARIABLES ON VARIOUS DIAPHRAGM

GAS METERS

The following are examples of various diaphragm gas meters and typical indexes found on the meter The index variables that

would be programmed in an ORION endpoint are identified

NOTE:

N

The index shown in the meter photograph may not be the exact same index shown in detail in the

corresponding index photo

Specific identification criteria of the index variables are explained in Section 1 of this manual

ELSTER AMERICAN AC-250

Drive 2 cu ft /rev

Index Resolution 100 cu ft

# Dials 4

Consumption Reading 6722

Subcounts 10

Pressure Factor 1 0

Meter Drive Direction of Rotation CCW

Programming Guide

Page 25

July 2013