ORION ME

The ORION ME tab displays when an

ORION ME endpoint is selected from the

list on the Account Records screen
The ORION ME tab displays any extended

status information collected from the

endpoints with work items
Work items are set when creating the route

file Refer to

"Load Collectors" on page 19

for more information
Extended status can be collected via

RF as part of regular route reading

The Configuration tab Value fields

automatically populate when extended

status information is requested from

the endpoint

Configuration

Field Name

Value (All fields are read only)

Meter Type

Options are: RTR or Unspecified; ENC; Gas Integral; Gas Remote; ELCD; Permalog; MAG; C700D; HRE

Meter Model Code

Meter model fills when extended status is received

Pressure Factor Code (GAS)

Informational data programmed through the IR port

Unit of Measure Code

Cubic Meters; Cubic Feet; Gallons; Imperial Gallons; Liters

Dials (ENC, GAS, ELCD)

Number of dials: 4; 5; 6; 7; 8

Meter Direction (GAS, ELCD)

Flow direction: 0 = counterclockwise; 1= clockwise

Encoder Type (ENC, ELCD)

Options are: Not Set; Ind Standard; Neptune ProRead; Elster/AMCO Scancoder; Neptune ARB V;
Elster/AMCO Invision; Sensus Fixed Format; Other

Meter Reading Changed Date

Index changed date

First Programmed Date

Date fills when first programmed through the IR port

Last Programmed Date

Date fills when last programmed through the IR port

Extended Status

Endpoint data fills when requested

Firmware Version

Endpoint firmware version number fills when requested

Latitude

This value does not fill for ORION ME

Longitude

This value does not fill for ORION ME

Device Conditions

Displays all conditions indicated by the latest Extended Status See

"Status" on page 29

for a list of

device conditions