Paragraph 1-55 – 1-55

1-55. BACK LIGHTING MAINTENANCE. Bulb
replacement is accomplished as follows:

a. Non-Explosionproof (See figures 10 and 11)

1. Disconnect power and electrical wires to shell

assembly.

2. Remove four (4) screws (10-32 x 3/8) holding shell

assembly to housing.

3. Slide out shell assembly.

4. Remove and replace defective fluorescent bulb (G.E.

P/N F20T12/D) and/or starter (G.E. P/N FS-2) as required.

5. Slide shell on housing and align.

6. Reinstall screws removed in second step.

7. Reconnect electrical wires disconnected in first step.

b. Explosionproof (See figures 10 and 12)

1. Disconnect power, conduit, and electrical wires to

shell assembly.

2. Remove four (4) screws (10-32 x 3/8) holding shell

assembly to flowmeter housing.

3. Slide out shell assembly.

4. Remove upper cap (end opposite conduit connection)

by turning cap counter-clockwise.

5. Remove and replace defective fluorescent bulb (G.E.

P/N F15T12/CW) and/or starter (G.E. P/N FS-2) as required.
Maintenance instructions for this operation are printed on the
cap inside face.

6. Reinstall the cap removed in the fourth step.

7. Slide shell assembly on flowmeter housing and align.

8. Reinstall screws removed in second step.

9. Reconnect electrical wires and conduit disconnected in

first step.