REGISTER OPERATION

The following describes register operation and program settings for all four Industrial Oval Gear (IOG) Series registers:

Industrial Standard (ILR 700), Industrial Pulse (ILR 710), Industrial Quadrature/Dual Pulse (ILR 720) and Industrial Analog

(ILR 730) See “"Additional Programming: Industrial Analog and Industrial Pulse (ILR 710 & ILR 730)" on

page 15

The Pulse

Transmitter (ILR 740) wiring is indicated on

page 21

The Pulse Transmitter (ILR 741) wiring is indicated on

page 22

The register display consists of two rows of seven-segment digits, status, unit of measures, flow rate and battery indicators

Operating function settings and programming are provided using the TOTAL and RESET buttons

Figure 3E: Register Display and Buttons

Normal Operation

(For models ILR 700, 710, 720 and 730)
To enter normal operation mode: When the screen is blank after exiting programming mode or upon initial use, press either

the TOTAL or RESET button once

Status

The status indicators are RESET and TOTAL

Totalizers

The top row of indicators is the Batch Totalizer This Totalizer displays the cumulative volume of flow through the meter with

six digits The Batch Totalizer totalizes in selected units of measure
To reset the Batch Totalizer, after 2 seconds of no flow, press and release the RESET button

OTEE:

N

For the ILR 720 model only, the Batch Totalizer can be reset by a low pulse on the external reset input

The bottom row of indicators display the Resettable Totalizer with five digits or the five least significant digits of the Non-

Resettable Totalizer RESET and TOTAL is indicated when the Resettable total is displayed in the five-digit lower row Only

TOTAL is indicated when the non-Resettable total is displayed
To toggle between the Non-Resettable totalizer and the Resettable Totalizer, press and release the TOTAL button
To display 11-digit Non-Resettable Totalizer:

1 While the Non-Resettable total is displayed, press and hold the TOTAL button for 2 seconds
2 The top row displays the 6 most significant digits; the bottom row displays 5 least significant digits

OTEE:

N

The Non-Resettable Totalizer normally displays 5 least significant digits

Flow Rate

PER MIN is displayed in conjunction with the unit of measure All flow rates are calculated in volume unit per minute

Industrial Oval Gear Meter and Register

Page 10