Maintenance, General safety information, Continued) – Blue Angel Pumps CSE40TODS User Manual

Page 3

Advertising
background image

3

www.blueangelpumps.com

sensor is 180° away from the inlet.

Make certain the incoming water

stream does not hit the surface (See

Figure 3B).

8. When a tether switch is used, rigid

dis charge pipe is required. If the

pump is allowed to move, the

tether switch could be re strict ed

by the basin wall, pre vent ing the

pump from operating.

Before removing

pump from basin

for service, always disconnect electrical
power to pump and control switch. For
any work on pump or switch, ALWAYS
unplug the power cord. Do not just turn
off circuit break er or unscrew fuse.

Maintenance

Make certain that

the pump is

unplugged before attempting to service
or remove any component. This pump is
assembled in the factory using special
equipment; therefore only authorized
service dealers or qualified electricians
should attempt to repair this unit.
Improper repair can cause an electrical
shock hazard.

The pump contains

oil that may be

under pressure because of heat. Let the
pump cool for a minimum of two hours
before servicing this unit.

1. Disassembly of the motor prior to

expiration of war ran ty will void the

warranty. It might also cause internal

leakage and damage to the unit. If

repairs are required, return the pump

to the dealer from whom it was

pur chased or call 1-888-636-6628. If

motor is ever disassembled the o-rings

must be replaced. Care must be taken

to ensure that all seals do not leak.

2. After the basin cover is removed

and necessary dis charge piping

disconnected, lift pump from basin.

3. Pump should be checked on a

regular basis for proper op er a-

tion. If anything has changed since

unit was new, the unit should be

removed and repaired or replaced.

Only qualified electricians or service

peo ple should at tempt to repair

this unit. Improper repair and/or

assembly can cause an electrical

shock hazard.

4. Place the pump in a suitable area

where it can be cleaned thoroughly.

Remove all scale and deposits on pump.

5. Submerge the complete pump in a

disinfectant so lu tion (10% chlorine

bleach solution) for at least one

hour before handling the pump.

6. Clean all dirt and deposits from the

pump float. Make sure float moves

freely after cleaning.

7. Clean all dirt and deposits away

from pump inlet and volute

8. Clean water sensor surface (model

BCAPSE40).

This pump contains

dielectric motor

oil for lubrication and motor heat

transfer. This oil can be harmful to the

environment. Check state environmental

laws before disposing of this oil. This

oil can be harmful to aquatic life so

consideration should be exercised in the

application of this pump.

Check valve 45º

Vent

Inlet

Gasket

1/2 inch

Min.

Clearance

Basin

figure 3A - Prefabricated Basins

Check

valve 45º

Vent

Inlet

Gasket

*Orient the pump

so that the sensor is

180° away from the

inlet. Make sure the

incoming water stream

does not hit the sensor

surface.

Basin

figure 3B - Prefabricated Basins

figure 2 - Typical Installation

Upper level

drainage

Switch

2 inch

Check

Valve

45º Elbow

Washer

Dryer

Floor drain

Washer drain

Flange

Cleanout

Laundry tubs

Lavatory

Shower

Toilet

Vent pipe

Vent pipe

Sewage pump passes

2 inch dia. solids

Three prong grounded outlet equipped

with a ground fault interruptor

2 inch

Gate Valve

2 inch Discharge pipe

General Safety

Information

(continued)

CSE40M, CSE40T

CSE40T-2 and BCAPSE40

Advertising