Installation Instructions

BEWP10

The Professional’s Line

Water Powered Back-up
Sump Pump System

Description

The BEWP10 is a water powered
back-up sump pump. It does not
replace a regular pump. This pump
is designed for use with municipal
water systems and is inteded to be
used as an emergency backup to your
existing sump pump.

Unpacking

Inspect this unit before it is used.
Occasionally, products are damaged
during shipment. If the pump or
components are damaged, return
the unit to the place of purchase for
replacement. Failure to do so could
result in serious injury or death.

Safety Guidelines

This manual contains information
that is very important to know and
understand. This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help
recognize this information, observe
the following symbols.

Danger

indicates

an imminently hazardous situation
which, if not avoided, will result in
death or serious injury.

Warning

indicates

a potentially hazardous situation which,
if not avoided, could result in death or
serious injury.

Caution

indicates

a potentially hazardous situation which,
if not avoided, may result in minor or
moderate injury.

Notice

indicates

important information, that if not
followed, may cause damage to
equipment.

General Safety
Information

Do not use to pump fl ammable
or explosive fl uids such as
gasoline, fuel oil, kerosene,
etc. Do not use in a fl ammable and/or
explosive atmosphere. Pump should only
be used to pump clear water. Fatal injury
and/or property damage could result.

© 2007 Blue Angel™ Pumps

353300-002 7/07

If the basement has water
or moisture on the fl oor, do
not walk on wet area until all
power is turned off. If the shutoff box
is in the basement, call an electrician.
Remove pump and either repair or
replace. Failure to follow this warning
could result in fatal electrical shock.

A check

valve

must be used on the primary sump
pump discharge.

This

pump

must only be used to pump clear water.
This pump is not designed to handle
effl uent, salt water, brine, laundry
discharge or any other application
which may contain caustic chemicals
and/or foreign materials. Pump damage
may occur if used in these applications
and will void warranty.

Installation

Installation of this unit may take
several hours. Before disabling your
main pump, have ready an appropriate
means of evacuating the sump.

1. Turn power to main pump off.
2. Pump must be installed using 1¼”

or 1½” rigid PVC pipe. Do not use
fl exible drain hose.

Pump Installation

The BEWP10 can be installed with
a separate dedicated discharge line
(Figure 1, Method 1) or tied into the
existing sump pump line (Figure 2,
Method 2).

Unplug

the

existing AC pump. Failure to follow this
warning could result in fatal electrical
shock.

3. Verify that the existing AC pump

is in good working order. If the
AC pump is questionable, it is
recommended that the unit be
replaced.

4. Remove any silt or accumulated

debris from the sump pit and
surrounding area.

5. Locate the BEWP10 in an ideal

position in the sump pit. The
ideal position is approximately
2” from the bottom of the sump
pit and located so that it does
not interfere with any part of the
existing sump pump.

6. Method 1 Installation:

(Figure 1) Cut and dry-fi t rigid
PVC pipe to the discharge of the
water powered back-up pump.
Cement all fi ttings and discharge
pipe after all pipe has been cut
and dry-fi t together.

The

discharge

line installation will vary depending on
individual circumstances. Using sound
plumbing practices, route the discharge
pipe to an exterior wall by the shortest
path. Keep turns to a minimum because
they reduce the fl ow output of the pump.
The pipe that exits the building structure
should be sealed and sloped downward
so the water will not freeze in the pipe.

Method 2 Installation:
(Figure 2) Cut the existing main
pump discharge line and cement
a “T” or “Y” fi tting. Measure,
cut and dry-fi t the pipe required
to connect the BEWP10 to the
installed “T” or “Y” fi tting.
Cement all fi ttings and pipe.

7. Shut off the municipal water

supply. Install a rigid water
supply line to the sump area.
Include a shut-off valve in the
supply line. Flush the supply line
of all debris before installing the
automatic valve.

8. Connect the automatic valve

assembly with brass vacuum
breaker to the supply line. Is
should be located about 6” above
the basement fl oor or sump pit
cover. The supply line needs to be
supported.

9. Attach the hose coupling and

washer to the brass vacuum
breaker of the automatic valve
assembly.

10. Attach the “L” bracket to the

automatic control valve using the
two screws supplied.

11. Install the fl oat rod by threading

the two parts together. Using
the large coupler, secure the rod
connection by threading the top
screw to the top part and the
bottom screw to the bottom part.

12. Install a small coupler and the

fl oat to the fl oat rod by inserting
the fl oat rod through the center
of the fl oat. Insert a small coupler
about ½” above the bottom of
the fl oat rod and tighten the
fastener. Tighten the fi rst small
coupler installed.

For parts, product & service information

visit

www.blueangelpumps.com

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or fi le it for safe keeping.

Please read and save these instructions. Read carefully before attempting to assemble,
install, operate or maintain the product described. Protect yourself and others by
observing all safety information. Failure to comply with instructions could result in
personal injury and/or property damage! Retain instructions for future reference.

Advertising