Blue Angel Pumps BSSF20 User Manual

12 volt battery back-up systems, Bsp15, bsp25, Description

Advertising
background image

© 2011,
Blue Angel Pumps, Harrison, Ohio.

354000-002 7/11

12 Volt Battery
Back-up Systems

Operating Instructions and Parts Manual

BSP15, BSP25

Please read and save these instructions. Read carefully before
attempting to assemble, install, operate or maintain the product
described. Protect yourself and others by observing all safety
information. Failure to comply with instructions could result in
personal injury and/or property damage! Retain instructions for
future reference.

Description

The BSP15 and BSP25 are battery operated
back-up sump pump systems. It does
not replace a regular primary pump. It is
designed to provide protection in the event
household electrical power fails.

Unpacking

Inspect this unit before it is used.
Occasionally, products are damaged during
shipment. If the pump or components
are damaged, call our customer service
department at 1-888-636-6628.

Safety Guidelines

This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.

DANGER

indicates

an

imminently

hazardous situation which, if NOT avoided,
WILL result in death or serious injury.

WARNING

indicates

a

potentially

hazardous situation which, if NOT avoided,
COULD result in death or serious injury.

CAUTION

indicates

a

potentially

hazardous situation which, if NOT avoided,
MAY result in minor or moderate injury.

NOTICE

indicates

important

information, that if NOT followed, MAY
cause damage to equipment.

G eneral Safety Information

CALIFORNIA PROPOSITION 65

This product or its

power cord contains

chemicals known to the State of
California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.

GENERAL SAFETY

Do NOT

use to

pump fl ammable or
explosive fl uids such as
gasoline, fuel oil, kerosene,

The Professional’s Line

®

For parts, product & service information

visit www.blueangelpumps.com

REMINDER: Keep your dated proof of purchase for warranty purposes!

Attach it to this manual or file it for safekeeping.

etc. Do NOT use in a fl ammable and/or
explosive atmosphere. Pump SHOULD
only be used to pump clear water.
Personal injury and/or property damage
COULD result.

All wiring MUST be

performed by a

qualifi ed electrician. Failure to follow
this warning COULD result in fatal
electrical shock.

If the

basement

has water or moisture on the
fl oor, do NOT walk on wet
area until all power is turned
off. If the shutoff box is in the basement,
call an electrician. Remove pump and
either repair or replace. Failure to follow
this warning COULD result in fatal
electrical shock.

Do NOT

expose

battery to sparks or fl ames as
an explosion or fi re COULD
result.

Battery

acid is

corrosive. Avoid spilling on
skin or clothing. Eye
protection MUST be worn
when handling the battery.

A check valve MUST be

used on the primary

sump pump discharge (see Figure 1).

A ground fault circuit

interrupter is required.

This pump MUST only

be used to pump

clear water. This pump is NOT designed
to handle effl uent, salt water, brine,
laundry discharge or any other
application which MAY contain caustic
chemicals and/or foreign materials.
Pump damage MAY occur if used in these
applications and WILL void warranty.

Battery Requirements

1. Use only a new fully charged 12 V

deep cycle battery. Electrolyte level
must be checked and maintained
in accordance with manufacturer’s
guidelines.

2. Battery sizes that will fi t into the

battery box are 24C, 24VCM, 27C,
27CM, and 27F.

3. Battery recharge time will be

different at each installation. Under
normal conditions it will take two
to four days to bring a deep cycle
battery back to full charge after it
has been discharged. If electrical
power to the house is lost more
than once a week, consider keeping
a spare, fully-charged battery to
replace an exhausted battery for the
back-up sump pump.

Installation – BSP15

Installation of this

unit may take

several hours. Before disabling your
main pump, have ready an appropriate
means of evacuating the sump.

1. Turn power to main pump off.

2. Pump must be installed using 1-1/4

in. or 1-1/2 in. rigid PVC piping. A
check valve (not included) must be
installed between the ESP’s tee and
the main pump (see Figure 1).

3. Measure and cut discharge pipe so

that back-up pump is a minimum
of 1 in. above the main pump. This
will allow main pump to operate
normally (see Figure 1).

4. Check the fit of the components

before permanently attaching. Using
PVC cement, glue tee in place. Note
the up direction arrow on the tee; the
notch must be to the top or fl apper
valve will not work (see Figure 2).

BSP15

BSP25

Figure 1

LEAVE A 4 IN.

MIN. BETWEEN

BASIN LID

AND

BACK-UP

PUMP

LEAVE A 1 IN.

MIN. BETWEEN

BACK-UP AND

PRIMARY PUMP

CHECK
VALVE

Advertising