electrical System

(Continued)

use only control

box specified

for your pump. Make sure motor and
control box match (see Table 4, on page
3). Failure to do so WIll void warranty.

4. Install circuit protection and

component protection in compliance
national Electrical Code, Part 1.
Consult with appropriate code
officials for more information on
how to do this.

If main overload trips, look for the
following:
1. Shorted capacitor
2. Voltage problems
3. Overloaded or locked pump.
Single Phase, 2 Wire
two-wire pumps have two power supply
wires and one ground wire (Green). A
control box is not required. See Figure
1b for correct hookup for 230 volt
2-wire motors only.

Operating Instructions and Parts Manual

Deep Well Submersible Pumps

Cable Size

Volts

HP

14

(2 mm

2

)

12

(3 mm

2

)

10

(5 mm

2

)

8

(7 mm

2

)

6

(13 mm

2

)

4

(21 mm

2

)

3

(25 mm

2

)

2

(34 mm

2

)

1

(41 mm

2

)

0

(50 mm

2

)

1/2

400

(121.9)

650

(198.1)

1020

(310.9)

1610

(490.7)

2510

(765)

3880

(1182.6)

4810

(1466.1)

5880

(1792.2)

7170

(2185.4)

8720

(2657.9)

230

3/4

300

(91.4)

480

(146.3)

760

(231.6)

1200

(365.8)

1870

(570)

2890

(880.9)

3580

(1091.2)

4370

(1332)

5330

(1624.6)

6470

(1972.1)

1

250

(76.2)

400

(121.9)

630

(192)

990

(301.8)

1540

(469.4)

2380

(725.4)

2960

(902.2)

3610

(1100.3)

4410

(1344.2)

5360

(1633.7)

nOTe: Specified maximum wire lengths are valid with motor voltage greater than or equal to 95% of service entrance
voltage and motor running at maximum nameplate amperes. If service entrance voltage is at least motor nameplate voltage
under normal load conditions, 50% additional length is permissible for all sizes shown.

Table 3 - Power supply wire (cable) length in feet (m)
1 phase, 2 or 3 wire cable, 60 Hz (copper wire size—service to motor)

HP

Voltage

Wires

Pump Model

no.

Control Box

no.

1/2

230

3

tB50S10-2

16965-002

1/2

230

2

tB50S10-2

none

1/2

115

2

tB51S10-4

none

3/4

230

3

tB75S10-2

16966-002

3/4

230

2

tB75S10-4

none

1

230

3

tB100S10-2

16967-002

Table 4 - Control box chart

L1 M1

M2

L2

CONTROL

BOX

L1L2R Y B

FUSED

DISCONNECT

SWITCH

115V or

230V LINE

GROUND

RED

YELLOW

BLACK

PRESSURE

SWITCH

WELL

CASING

GROUND

L1 M1

M2

L2

FUSED

DISCONNECT

SWITCH

TO LINE

GROUND

RED

BLACK

PRESSURE

SWITCH

WELL

CASING

GROUND

(GREEN)

Follow color coding when

connecting control box wires.

(Yellow = Y, Red = R, Black = B)

figure 1a - 3 wire, 1/2-1HP quick

disconnect box

figure 1b - Single phase, 2 wire

connections

Advertising
This manual is related to the following products: