3.0

C-1500N Features

!

Double-ball ceramic check valves.

!

PVDF (Kynar) valve assemblies.

!

Viton o-rings.

!

High outlet pressure capability of 125 PSIG.*

!

Easy access, top mounted mechanical feed rate adjustment.

!

Ball bearing supported motor drive shaft.

!

Permanently lubricated ball bearing motor.

!

20:1 adjustment turn down ratio.

!

Acceptable for outdoor use. (NEMA 3R; IP23)

!

Corrosion resistant Valox housing.

!

Easy servicing.

!

Includes suction tube foot valve & strainer, suction tube weight, suction tubing,

discharge tubing and injection fitting with internal back-flow check valve and
mounting hardware.

*

Most models.

4.0

How To Install the C-1500N

Note: All diagrams are strictly for guideline purposes only. Always consult
an expert before installing the C-1500N into specialized systems.
The C-1500N should be serviced by qualified persons only.

4.1

Mounting Location

Choose an area located near the chemical supply tank, chemical injection point
and electrical supply. Although the pump is designed to withstand outdoor
conditions, a cool, dry, well ventilated location is recommended. Install the
pump where it can be easily serviced.

!

Mount the pump to a secure surface or wall using the enclosed hardware. Wall

mount to a solid surface only. Mounting to drywall with anchors is not
recommended.

!

Keep the outlet (discharge) tubing as short as possible. Longer tubing

increases the back pressure at the pump tube.

!

Do not mount the pump directly over your chemical container. Chemical

fumes may damage the unit. Mount the pump off to the side or at a lower
level than the chemical container.

!

Mounting the pump lower than the chemical container will gravity feed the

chemical into the pump. This “flooded suction” installation can reduce the
time required to prime the pump. Install a shut-off valve, pinch clamp or other
means to halt the gravity feed to the pump during servicing.

!

Your solution tank should be sturdy. Keep the tank covered to reduce fumes.

!

Be sure your installation does not constitute a cross connection with the

drinking water supply. Check your local plumbing codes.

Proper eye and skin protection must be worn

when installing and servicing the pump.

!