Blue-white, Wiring diagram, K-factors (pulses per fluid volume) – Blue-White Flow Verification Sensor (FVS) User Manual

Page 3: Sensor

Advertising
background image

Industries, Ltd.

Blue-White

Industries, Ltd.

®

Page 2

FVS

Wiring Diagram

Foot Strainer

Strainer Adapter

Strainer Body

Screen Strainer

Suction Tubing

Part Number

C-340X

Exploded View

Your flow verification sensorpackage includes a Foot Strainer (see diagram below). This strainer will prevent any small
particles from entering and clogging the Micro Body. Diaphragm pumps will require a strainer and a check valve. The part
number for the strainer that includes a check valve is C-340A. Blue-White peristaltic pumps do not require a check valve.

Sensor

+

_

Red

0v dc

(True digital Square-wave output)

+5v dc

Bare

Black

(Ground)

Sensor connections:
Input voltage (vdc) 8 to 28 vdc
Output voltage (v) “high state” 4 80 v dc min (5 vdc normal)
Output voltage (v) “low state” 0 2v dc max

+ 5 Vdc (signal output)

8 to 28 Vdc (Positive)

K-Factors (pulses per fluid volume)

30-300

1

100-1000

2

200-2000

3

300-3000

4

500-5000

5

700-7000

6

181,336

81,509

42,051

25,153

15,737

9,375

Flow Range

(ml/min)

Body

Size

Pulses per

Gallon

21,535

13,752

6,646

4,157

2,477

Pulses per

Liter

47,909

Useful formulas

60 / K = rate scale factor

rate scale factor x Hz = flow rate in volume per minute

1 / K = total scale factor

total scale factor x n pulses = total volume