Specifications, Electrical, Environmental – Crystal WT Series Panel Mount Digital Pressure Gauge User Manual

Page 5: Power

Advertising
background image

Specifications

5

XP2i External Power Supply Operation Manual

Specifications

electrIcal

AC Input Voltage . . . . . . . . . . . . . . . . . 90 VAC to 264 VAC

AC Input Frequency . . . . . . . . . . . . . . 47Hz to 63Hz

AC Input Current . . . . . . . . . . . . . . . . . 0.5Arms (120VAC), 0.25Arms (240VAC)

AC Inrush Current (Cold) . . . . . . . . . 30A max. (120VAC), 60A max. (240VAC)

AC Surge Immunity . . . . . . . . . . . . . . IEC 61000-4-5, Level 3

enVIronmental

temperature

Operation . . . . . . . . . . . . . . . . . . . . . . . 0 to 35° C

Storage . . . . . . . . . . . . . . . . . . . . . . . . . . -25 to 85° C

Humidity . . . . . . . . . . . . . . . . . . . . . . . . 10% to 90% RH (Non-condensing)

Emissions . . . . . . . . . . . . . . . . . . . . . . . . FCC Class B, EN 55022 B

Immunity, EN 50082-1 . . . . . . . . . . . 61000-4-2, Level 3

61000-4-3, Level 2
61000-4-4, Level 2
61000-4-3, Level 2

power

Power On Indicator . . . . . . . . . . . . Green LED

DC Output Cord/Connector . . . . 1.8 meter (70.8 inches)

2.1mm x 5.5mm Coaxial Plug, Center Positive

!

WARNING: do not operate serial interface within a hazardous atmosphere.