Temperature (Operating and Storage)

Operating & Compensated . . . . . . . -20 to 50°C (-4 to 122°F).

Storage . . . . . . . . . . . . . . . . . . . . . . . . . . - 40 to 75°C (-40 to 167°F).

Humidity

<95% Relative, non-condensing

IP Rating

IP67 rated enclosure (1m immersion for 30 min) per IEC 60529

Electrical Connection

Electrical Connection . . . . . . . . . . . . mini-USB B (environmentally sealed chassis connector).

nVision under USB power consumes less than 100 mA.

!

WARNING: The mini USB B connector shall not be used within the hazardous atmosphere. It shall

be used in the non-hazardous atmosphere with either “Safety Extra Low Voltage
Circuits” (SELV) or “Protective Extra Low Voltage Circuits” (PELV). The USB connector
has a Um of 6V.

SELV and PELV definitions per IEC60079-11 are:

Safety extra-low voltage (SELV): Extra-low voltage system (i.e. normally not exceeding 50 VAC or 120
V ripple-free DC) electrically separated from earth and from other systems in such a way that a single
fault cannot give rise to an electrical shock.

Protective extra-low voltage (PELV): Extra-low voltage system which is not electrically separated from earth but which otherwise satisfies the requirements
for SELV.

Note:

A 50V center-tapped earth system is a PELV system.

Mounting

Permanent Mounting . . . . . . . . . . . . four M4 x 0.7 threaded inserts: 8mm deep (see drawing for location)

Enclosure

Impact resistant injection molded housing and elastomeric protective boot compatible with common industrial fluids, including Skydrol.

Weight: 680g (1.5 lbs) including one each PM and RTD100 module, 4AA battery module, and protective boot.

51

2.00

0.60

15

37

1.44

25

SENSOR

DIAPHRAGM

SURFACE

1.00

ALL DIMENSIONS ARE IN MILLIMETERS [INCHES]

RTD100 MATING CONNECTOR
FOR RTD PROBE SHOWN
INSTALLED

RTD100 CONNECTOR
SHOWN WITHOUT
PROTECTIVE CAP

PHILLIPS X 4

THUMBSCREWS WITH

SHOWN

4AA BATTERY MODULE

8MM [0.31 in] DEEP

THREADED INSERTS

M4 X 0.7

4 PLACES

CL

40 X 12 [1.6 X 0.5]

MOUNTING SURFACE

2 PL

21

0.81

1.20

2 PLACES

5.50

140

30

0.75

FLATS

WRENCH

19

3.93

ACCESS

BATTERY

100

2.88

ACCESS

73

BATTERY

20

0.79

MINI USB-B

ACCESS

FLAP

[2.41]

60

MEDIUM PRESSURE FEMALE (MPF)

PRESSURE MODULE (PM) SHOWN

CRYSTAL CPF SYSTEM:

RTD100 MODULE SHOWN
WITH INCLUDED
PROTECTIVE CAP

[7.08]

178

110

[4.38]

204

MAXIMUM

WITH TWO

PRESSURE

MODULES

8.05

TUBE SYSTEM

(1/4" MEDIUM PRESSURE

WITH 7/16"-20 INTERNAL THREADS)

The nVision enclosure

Advertising
This manual is related to the following products: