OPERATION
Selecting Engineering Units
Four sets of jumper pins are located in the back of the meter, between the
meter and the adder board. Move the jumper to fit over the appropriate pins
which correspond to the desired engineering units. See Figure 1.

Selecting Decimal Point Position
Four decimal point positions are available on the digital panel meter. Move
the jumper to correspond to the desired decimal point location. See Figure
2.

Setting Min/Max Display Value J1, J2, J3 (See Figure 3 & 4):
If:
The minimum display is ≤ 0 or
Minimum display is > 0 and the (maximum display minimum display) >
5; The J1, J2 & J3 should be all set to the top jumper (see Figure 3).

If:
The minimum display is > 0 and the (maximum display minimum display)
< 5; The J1, J2 & J3 should be all set to the bottom jumper (see Figure 4).

MAINTENANCE/REPAIR
Upon final installation of the Series DPMW, no routine maintenance is
required. The Series DPMW is not field serviceable and should be returned
if repair is needed. Field repair should not be attempted and may void
warranty.

WARRANTY/RETURN
Refer to “Terms and Conditions of Sale” in our catalog and on our website.
Contact customer service to receive a Return Goods Authorization number
before shipping the product back for repair. Be sure to include a brief
description of the problem plus any additional application notes.