Dwyer ULL User Manual

Page 17

Advertising
background image

Appendix A

Gas Factor Table
The following table contains 32 different types of gasses and their factor for
compensating the sound velocity:

Appendix B

Installation Tips

Page 16

Distance to tank walls

Surface
Acoustic noises

Electrical interference

Tank installation

Tank installation

Sensor

Must Be

Must Be
Must Be

Must Be

Must Be

Must Be

Must Be

At least 19.69˝ (50 cm) from
walls + 3.94˝/3.28 ft (10 cm/1
m) range.
Fixed on a horizontal surface.
Far away from acoustic
noises and vibrations.
Shielded away from power
and sensor cables.
Far away from tank inlets,
outlets, physical obstacles.
Far away from tank inlets,
outlets, physical obstacles.
Exactly perpendicular to the
surface of the target.

1) Choosing Location

Extension pipes (1)

Extension pipes (2)

Extension pipes (3)

Must Be

Must Be

Must Be

At least 3˝ (7.62 cm) internal
diameter and 19.69˝ (50 cm)
long (from sensor low edge to
pipe low edge).
With completely smooth
interior surface.
Installed with a flange/not
protruding into the tank.

2) Handling Dead Zone

Voltage

A battery

Ripple and noise
Type

Rechargeable supply

Must Be

Must Be

Must Be
Must Be

Must Be

At least 12 VDC on unit
terminals.
Rated higher than 12 volts
due to normal voltage drop.
Not exceeding 100 mV.
Preferably regulated switching
PS (avoid rectified PS).
Non operational when
switched to recharge.

3) Power Source

PLC Connections

Barrier

Must Be

Must Be

As specified in the user
manual, preferably grounded.
Connected in EX zones,
grounded.

4) 2-Wire Interface

Tank Height,
Level/Distance
4 to 20 settings

5 cm margin

Scan distance (1)

Scan distance (2)

Scan distance (3)

SBD (1)

SBD (2)

Must Be

Must Be

Must Be

Must Be

Must Be

Must Be

Must Be

Must Be

Configured correctly.

Defined (consider the
extension pipe).
Kept between pipe low edge
and full level.
Preferably be executed in all
applications.
Executed when the tank is
empty.
Performed after the old stored
data is cleared.
Set up in flange and
extension pipe installations.
At least 1.97˝ (5 cm) before
the pipe edge.

5) Configuration

Factor
0.62
0.63
0.74
0.54
0.99
1.26
0.92
0.53
0.41
0.37
0.56
0.77
1.01
0.38
0.68
0.71
0.90
0.71
0.95
2.93
3.79
0.89
0.62
1.29
0.71
1.30
1.01
0.63
1.02
0.72
0.61
0.57

Symbol
C

2

h

4

o

2

C

3

h

6

o

C

2

h

4

o

C

2

h

3

c

1

o

C

2

h

2

H

3

n

Ar
C

6

H

6

Br

2

Cbrclf

2

CH

3

COCH

2

CH

3

CO

2

CO
CCI

4

Cl

2

C

2

h

6

o

C

2

h

6

C

2

h

6

o

C

2

h

4

He
H

2

H

2

S

C

3

h

8

o

CH

4

Ch

6

n

2

Ne
N

2

CH

3

NO

2

O

2

C

3

H

8

C

3

H

8

O

C

4

H

8

O

Gas
Acetic Acid
Acetone
Acetaldehyde
Acetyl Chloride
Acetylene
Ammonia
Argon
Benzene
Bromine
Bromochlorodifluoromrthane
Butanone
Carbon Dioxide
Carbon Monoxide
Carbon Tetrachloride
Chlorine
Dimethyl Ether
Ethane
Ethanol
Ethylene
Helium
Hydrogen
Hydrogen Sulfide
Isopropyl Alcohol
Methane
Methyl Hydrazine
Neon
Nitrogen
Nitromethane
Oxygen
Propane
Propanol
Tetrahydrofuran

Advertising
This manual is related to the following products:

ULB, ULF