Wiring diagrams – Aiphone LAF-20C User Manual

Page 3

Advertising
background image

3a. SINGLE MASTER SYSTEM, NO ALL CALL

1
2
3
4
5

~

20

E
E
E
E

-

C
R
Y

P1
P2
P3

+

-

LAF-20C

+

-

PS-12C

LE-A

1

E

-

LE-A

LE-D

Pg. 3

3b. DUAL MASTER SYSTEM WITH MASTER-TO-MASTER COMMUNICATION

1

E

-

1

E

-

LE-D

1

E

-

NOTES:
Two wiring method can be used:
1. 2 conductor homerun to each sub station from the master.
(Single master system only.)

2. Run multi-conductor wire in a daisy-chained fashion with 2
common wires (E & -) plus one individual wire per station on the run.

Remove jumpers between E & - when daisy-chained method is used.

3. To protect system from power surge, install SA-1 arrestors at master

station. One SA-1 is required for every two wires connected to

master.

1
2
3

~

19

E

-

C

20

R
Y

P1
P2
P3

+

-

LAF-20CA

+

-

PS-12C

LE-DA

1

E

-

LE-DA

LE-DA

1

E

-

1

E

-

LE-DA

1

E

-

LAF-20CA

1
2
3

~

19

E

-

20

C
R
Y

P1
P2
P3

+

-

Master-to-master
communication is shown on
channel 20 of each master.

Y, P1, P2, P3 terminals
used only if All Call
Adaptors are included.

3

WIRING DIAGRAMS

WIRING NOTE:
The following sub stations
are wired as shown above:
· LE-A, LE-AN
· LE-B, LE-BN
· LE-D, LE-DA

Remove E/-
jumpers

SA-1

SA-1

SA-1 for optional
surge protection
(See note #3.)

SA-1

All "E" terminals are

common internally.

RY-AC

Red

Blk

Wht

Yellow

To external signalling device and power
(E.g. Station #19 will actvate ext. device
when it calls in to master.)

RY-AC for external signalling
when sub calls

Advertising