Dwyer DDM-01 User Manual

Dwyer instruments, inc, Model ddm-01 laser distance meter, Bulletin te-ddm-01

Advertising
background image

Bulletin TE-DDM-01

The Model DDM-01 Laser Distance Meter offers quick measurement of
distances up to 229.7 feet (70 meters) with the click of a button. It is also
able to easily make area and space calculations and volume measure-
ments from what it records. Another feature of the Model DDM-01 is that
it is able to use the Pythagorean Theorem to indirectly calculate the height
of an object. The meter can read out in feet, inches, or meters and in-
cludes a backlight for use in dark areas.

PRODUCT OVERVIEW

A. LCD

G. Pythagorean I, II, & III

B. Add/Unit Switch

H. Power Button/Clear

C. Measure/Continuous Measure

I. Reference Switch/Laser Pointer

D. Measuring Function

J. Battery Cover

(Area, Dimension, Stake Out)

E. Timer/Memory

K. Laser Emitting Window

F. Subtract/Backlight

L. Receiving Window

Specifications - Installation and Operating Instructions

Model DDM-01 Laser Distance Meter

L A S E

R DIS T A NC E ME T E R

Laser

distance meter

DDM-01

S

+/U

LED

/-

MEAS

2

[51.75]

1-1/4

[31.88]

4-5/8

[116.69]

SPECIFICATIONS
Range:
0.16 to 229.7 feet (0.05 to 70 m).
Accuracy: ±0.005 feet (±1.5 mm).
Display: Three line LCD (top two with 4 digits/bottom with 5 digits).
Resolution: 0.001 feet (0.001 m).
Response Time: 0.5 s.
Laser Type: 650 nm, class 2, <1 mW.
Beam Size: 25 mm at 30 m.
Temperature Limits:

Operating: 23 to 104°F (-5 to 40°C);
Storage: -4 to 140°F (-20 to 60°C).

Power Requirements: (2) 1.5 V AA carbon zinc batteries, included,
user replaceable.
Weight: 21.6 oz (612.35 g).
Agency Approvals: CE, RoHS.

L A S E

R DIS T A NC E ME T E R

Laser

distance meter

DDM-01

S

+/U

LED

/-

MEAS

A

B

C

D

E

F

G
H
I

J

K

L

Figure 1

1. Measuring Function Area

7. Minimum Distance

Measuring Volume Measuring

8. Stakes Direction Indicator

2. Indirect Measuring Single Height

9. Main Display & Units

Sum of Two Heights

10. Memory

Difference of Two Heights

11. Countdown Measuring

3. Laser Indicator

12. Battery Status

4. Measuring Reference

13. Sub-Display & Units

5. Add and Subtract
6. Maximum Distance

max

min

ftinm

ftinm

ftinm

1

2

3

4

5

6

7

8

9

10

11

12

13

Figure 2

DWYER INSTRUMENTS, INC.

Phone: 219/879-8000

www.dwyer-inst.com

P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A.

Fax: 219/872-9057

e-mail: [email protected]

If there are two settings separated by a “/” for one button, the set-
ting that is listed before the slash will be activated when the but-

ton is pressed once. If it is listed after the slash, then it will be activated when the but-
ton is pressed and held.

NOTICE