Hoyles EXITGUARD door alarm with integral Keypad control User Manual

Hoyles electronic developments ltd, Exitguard ex200 series installation instructions

Advertising
background image

D

o

o

r S

w

itc

h

C

o

n

ta

c

t R

d

/Y

l

EX204 Battery powered for use where a 4. OUT OF THE BOX factory default settings
separate supply of power is not available and

are suitable for most applications. On first use

the protected door is opened infrequently or

we recommend that you use these settings to

there is no requirement to sound the sounder

test the EXITGUARD. They can be changed

for long periods. Can be powered from 12vdc if

later to suit local requirements. Test by entering

necessary. (Discard batteries)

the user code and pressing I for Chime Mode.
A chime will be heard each time the door is

EX205 12vdc powered for use where the

opened.

protected door may be opened frequently or

Advanced Installation

the integral sounder needs to sound for

The following parameters can be changed

protracted periods. This version can also be

through the keypad:

interfaced with other equipment. There are volt

1. User Code

free relay contacts to separately signal

2. Select one of six different alarm tones

ON/OFF status and alarm conditions at remote

3. Change auto re-arm delay 0 - 88 secs

points. Cannot be powered from batteries.

4. Change Door Open Too Long (DOTL1)

EX206 230vac powered version where the

delay for keypad reset mode 0 secs - 88 mins.

protected door may be opened frequently or

5. Change DOTL2 delay for auto reset mode

the sounder needs to sound for protracted

0secs - 88mins.

periods. There is a volt free alarm relay contact.

6. Switch Bleep In Off (BIO) on or off.

This version is supplied with 6 x AA alkaline

7.Add or change a Reset/Pass Code

batteries for standby - Note: the batteries will

8. Add or change a Manager Code.

not power the alarm relay.

OUT OF THE BOX User Operation.

All versions have key pad control, integral

There are four possible modes:

sounder with programmable tones, 5 mode

Off Mode

LEDs, a front/back acting tamper switch and a

Chime Mode I

logic output to signal to a MULTIGUARD

Keypad Reset Mode II

indicator from HED. All are supplied with a door

Auto re-arm Mode III

contact, fixing screws and door warning label.

Quick Install

When the User Code is entered the
EXITGUARD is interrogated and one of the

EXITGUARDS are NOT intended for external

mode LEDs illuminates to indicate the current

use and to avoid damage should not be fixed to

status.

the protected door itself.

After the User Code is entered there is a 5sec

1.The door contact is in two parts; the magnet

window to change the mode, eg. If the current

should be fixed to the door and the contact with

mode is OFF and it is desired to switch to the

its cable fitted to the frame. The cable should

Keypad Reset mode just enter II ie 2 on the

be taken to the EXITGUARD and connected as

keypad. Within 5secs the LED will extinguish. If

shown. A is the alarm input for the switch

a mistake has been made this can be rectified

element (BL/YL) of the contact and T is from

before the LED extinguishes by simply

the tamper loop (RD/BK) of the contact.

selecting the desired mode, the LED indication

2. Make all connections, apply power, a double

will change to the new mode.

bleep will be heard and the four mode LEDs will

If the Auto re-arm mode is selected then the

illuminate.

factory default period of 30secs will be used

3. When the EXITGUARD leaves the factory

unless set up differently. (see programming

there are no codes in memory. The four

instructions to change the Auto re-arm period

illuminated red LEDs are inviting you to

and other functions)

enter a User Code. This must be a four digit
memorable code. As the code is entered
acknowledge bleeps are heard and each of
the mode LEDs will extinguish. The code is
now stored in memory and the EXITGUARD
will emit a double bleep and should be in the
OFF mode.

B

K

R

D

P

P

H

ED

D

o

o

r S

w

itc

h

ta

m

p

e

r

lo

o

p

B

l/B

k

T

h

e

s

e

r

e

la

y

c

o

n

ta

c

ts

c

h

a

n

g

e

s

ta

te

w

h

e

n

th

e

E

X

IT

G

U

A

R

D

is

a

rm

e

d

.

E

X

2

0

5

o

n

ly

.

T

h

e

s

e

r

e

la

y

c

o

n

ta

c

ts

c

h

a

n

g

e

s

ta

te

w

h

e

n

a

n

a

la

rm

c

o

n

d

iti

o

n

is

g

e

n

e

ra

te

d

.

E

X

2

0

5

&

E

X

2

0

6

1

6

v

a

c

M

R

v

e

+

v

e

-

T

o

T

h

e

s

e

te

rm

in

a

ls

a

re

o

n

ly

u

s

e

d

o

n

E

X

2

0

4

&

E

X

2

0

6

If

re

q

u

ire

d

th

e

ta

m

p

e

r s

w

itc

h

T

o

c

a

n

b

e

:

a

.

w

ire

d

in

s

e

rie

s

w

ith

th

e

R

e

d

o

r B

la

c

k

d

o

o

r s

w

itc

h

ta

m

p

e

r l

o

o

p

to

g

iv

e

a

n

a

u

d

ib

le

a

la

rm

a

t a

n

y

ti

m

e

.

b

. w

ire

d

in

s

e

rie

s

w

ith

th

e

B

lu

e

o

r Y

e

llo

w

o

f t

h

e

d

o

o

r

s

w

itc

h

c

o

n

ta

c

t p

a

ir

to

g

iv

e

a

n

a

la

rm

c

o

n

d

iti

o

n

o

n

ly

w

h

e

n

th

e

E

x

itg

u

a

rd

is

a

rm

e

d

.

c

. w

ire

d

to

a

r

e

m

o

te

d

e

v

ic

e

to

g

iv

e

a

w

a

rn

in

g

a

t a

re

m

o

te

lo

c

a

tio

n

.

d

. i

g

n

o

re

d

a

n

d

n

o

t c

o

n

n

e

c

te

d

a

t a

ll.

T

h

e

o

n

b

o

a

rd

ta

m

p

e

r s

w

itc

h

is

c

o

n

n

e

c

te

d

to

th

e

s

e

tw

o

te

rm

in

a

ls

, T

o

If

th

e

ta

m

p

e

r s

w

itc

h

is

r

e

q

u

ire

d

fi

t t

h

e

s

p

rin

g

e

n

s

u

rin

g

c

o

n

ta

c

t w

ith

th

e

w

a

ll

w

h

e

n

th

e

li

d

is

fi

tte

d

,

a

n

d

o

p

e

ra

te

s

w

h

e

n

th

e

li

d

is

r

e

m

o

v

e

d

.

A

T

1

2

v

d

c

E

X

2

0

4

A

p

p

ly

1

2

v

d

c

(

1

4

0

m

a

m

a

x

) h

e

re

if

r

e

q

u

ire

d

.

E

X

2

0

5

A

p

p

ly

1

2

v

d

c

(

1

6

5

m

a

m

a

x

) h

e

re

.

E

X

2

0

6

1

2

v

d

c

a

v

a

ila

b

le

h

e

re

@
1

0

0

m

a

m

a

x

w

h

e

n

m

a

in

s

p

o

w

e

r i

s

a

v

a

ila

b

le

.

EXITGUARD EX200 series Installation Instructions

RELAY 1 RELAY 2

In

p

u

t f

o

r F

ir

e

D

o

o

r

C

h

e

c

k

e

r

(s

e

e

s

c

e

n

a

rio

4

) O

r

T

e

m

p

o

ra

ry

P

a

s

s

t

h

ro

u

g

h

(

s

e

e

s

c

e

n

a

rio

7

)

A

p

p

ly

1

2

v

d

c

+

v

e

to

in

v

o

k

e

F

ire

D

o

o

r C

h

e

c

k

e

r.

T

h

is

c

a

n

b

e

d

e

riv

e

d

fr

o

m

a

n

in

tr

u

d

e

r,

tim

e

c

lo

c

k

o

r k

e

y

s

w

itc

h

e

tc

..

A

p

p

ly

m

o

m

e

n

ta

ry

1

2

v

d

c

+

v

e

fo

r r

e

tu

rn

p

a

s

s

th

ro

u

g

h

.

F

a

c

to

ry

D

e

fa

u

lt

.

T

o

re

s

to

re

th

e

fa

c

to

ry

d

e

fa

u

lt

s

e

tti

n

g

s

d

is

c

o

n

n

e

c

t

p

o

w

e

r

c

o

m

p

le

te

ly

fo

r

a

b

o

u

t

1

0

s

e

c

s

. E

n

s

u

re

th

e

d

o

o

r c

o

n

ta

c

t &

ta

m

p

e

r l

o

o

p

a

re

o

p

e

n

.

M

o

v

e

th

e

S

Y

S

T

E

M

R

E

S

E

T

ju

m

p

e

r

J

1

f

ro

m

it

s

n

o

rm

a

l

p

o

s

iti

o

n

t

o

t

h

e

re

s

e

t p

o

s

iti

o

n

. R

e

-a

p

p

ly

p

o

w

e

r

fo

u

r

b

le

e

p

s

w

ill

b

e

h

e

a

rd

.

R

e

p

la

c

e

t

h

e

ju

m

p

e

r

to

t

h

e

n

o

rm

a

l

p

o

s

iti

o

n

.

T

w

o

b

e

e

p

s

w

ill

b

e

h

e

a

rd

a

n

d

th

e

fo

u

r

m

o

d

e

L

E

D

s

s

h

o

u

ld

b

e

illu

m

in

a

te

d

in

v

iti

n

g

y

o

u

to

e

n

te

r a

n

e

w

u

s

e

r

c

o

d

e

. R

e

-c

lo

s

e

th

e

ta

m

p

e

r &

d

o

o

r c

o

n

ta

c

t..

T

h

e

F

a

c

to

ry

d

e

fa

u

lt s

e

tti

n

g

s

a

re

a

s

fo

llo

w

s

:

U

s

e

r C

o

d

e

N

o

n

e

A

u

to

re

-a

rm

p

e

rio

d

3

0

s

e

c

o

n

d

s

D

O

T

L

1

d

e

la

y

0

0

s

e

c

o

n

d

s

D

O

T

L

2

d

e

la

y

0

0

S

e

c

o

n

d

s

S

o

u

n

d

e

r T

o

n

e

1

I

II

III

Chime mode

Off

Keypad reset mode

Auto re-arm mode

exitguard

Mode
LEDs

Power LED

Setup LED

N

O

C

O

M

N

C

N

O

C

O

M

N

C

S

Y

S

T

E

M

J

1

R

E

S

E

T

{

Z

1

Z

2

Z

3

Z

4

Z

5

Z

6

F

3

M
U

LT

IG

U

A

R

D

2

0

0

0

-

6

O

/P

to

o

p

tio

n

a

l M

U

L

T

IG

U

A

R

D

N

e

u

tr

a

l

E

a

rt

h

1

A

M
P

2

3

0

v

a

c

T

ra

n

s

fo

rm

e

r i

s

fi

tte

d

in

th

e

e

n

c

lo

s

u

re

b

a

c

k

b

o

x

a

n

d

is

p

re

-w

ire

d

to

th

e

c

irc

u

it

b

o

a

rd

.

E

X

2

0

6

M

a

in

s

P

o

w

e

re

d

V

e

rs

io

n

O

n

ly

D

W
G

N

o

: 6

0

1

1

2

Is

s

u

e

2

, N

o

v

2

0

1

3

1

4

5

6

7

8

0

2

3

II

II

II

III

III

Keypad

T. 01744 886600 F. 01744 886607 E. [email protected] W. www.hoyles.com

Hoyles Electronic Developments Ltd

N

O

R

M

R

E

S

E

T

8

m

m

(

m

a

x

g

a

p

)

M

a

g

n

e

tic

D

o

o

r C

o

n

ta

c

t.

F

it

to

d

o

o

r f

ra

m

e

a

n

d

p

ro

te

c

t f

ro

m

m

o

is

tu

re

M

a

g

n

e

t.

F

it

to

d

o

o

r

&

a

lig

n

w

ith

c

o

n

ta

c

t

Advertising
Table of contents