Advanced configuration

Alarm Data Levels tab, Priorities

Name

Description

Level

Add new priorities with level numbers of your choosing or use/edit
the default priority levels (numbers 1, 2 or 3). These priority levels
are used to configure the Initial alarm priority setting (see "Alarms
definition"
on page 184).

Name

Type a name for the entity. You can create as many as you like.

Sound

Select the sound to be associated with the alarm. Use one if the
default sounds or add more in Sound Settings (on page 186).

Alarm Data Levels tab, States

Level

In addition to the default state levels (numbers 1, 4, 9 and 11, which
can not be edited or reused), add new states with level numbers of
your choosing. These state levels are only visible in the Smart
Client's Alarm List.

Name

Type a name for the entity. You can create as many as you like.

Alarm Data Levels tab, Categories

Level

Add new categories with level numbers of your choosing. These
category levels are used to configure the Initial alarm category
setting (see "Alarms definition" on page 184).

Name

Type a name for the entity. You can create as many as you like.

Alarm List Configuration tab

In Available columns, use > to select which columns should be available in the XProtect Smart Client
Alarm List. Use < to clear selection. When done, Selected columns should contain the items to be
included.

Reasons for Closing
tabEnable

Select to enable that all alarms must be assigned a reason for
closing before they can be closed.

Reason

Add reasons for closing that the user can choose between when
closing alarms. Examples could be "Solved-Trespasser" or "False
Alarm
". You can create as many as you like.