GENERAL SAFETY INFORMATION 

 

      !  DANGER 

Failure  to  disconnect  the  power  source  before  installation  or  servicing  can  result  in  serious  injury  or 

death from electric shock. 

− Always disconnect the power source before servicing or installing the hand dryer. 

Failure to properly ground this unit could result in severe electrical shock and/or death. 

− This  hand  dryer  must  be  properly  grounded  (Earthed)  for  safe  operation.  An  identified  ground 

connection point is supplied on the hand dryer’s wall base. 

− We recommend GFCI protection in wet or damp locations or as required by local code. 

 

      !  WARNING 

Risk  of  fire,  personal  injury  or  property  damage  are  possible  if  local  or  national  codes,  or  safety 

recommendations are not followed. 

− Use only the electrical power (voltage and frequency) specified for the model hand dryer being installed. 
− Connect the hand dryer to the nearest suitable distribution panel. 
− To limit a voltage drop, and ensure efficient operation, use wire gauge as required by local or National 

Electrical Code. 

− Do not connect to a branch circuit with circuit breaker or fuse protection over 15 Amps.  
− All  automatic  model  hand  dryers  must  have  a  dedicated  15  Amp  circuit  as  required  by  Underwriters 

Laboratories, Inc. (UL). 

− Route all field wiring away from moving parts within the hand dryer. 

      !  CAUTION 

Improper mounting could result in personal injury or property damage. 

− Follow the mounting recommendations in Table 1. 

 

INSTALLATION 

 

IMPORTANT:  Consult  local  and  general  regulations  before  performing  dryer  installation.  Ensure  that  the 
electrical network is not overloaded.  

1. Disconnect the power source. 
2. Use the security hex key supplied to remove the cover mounting screws. Remove the cover. 
3. Place  the  hand  dryer  base  on  the  wall  at  desired  location  using  Table  1  to  determine  the  recommended 

mounting height. When two or more dryers are installed, they should be placed no closer than 24” (60 cm) 
from center to center. Mark the location of the four mounting bolt holes and the wire entry hole. 

4. For recessed wiring, carry the supply wire to the dryer base plate knockout and attach with an acceptable 

cable clamp. The dryer requires two conductors for power plus a separate ground wire. 

5. For  surface  wiring,  remove  the  knockout  located  at  the  bottom  left  corner  of  the  cover.  Pass  the  supply 

wire according to local code, through the knockout and attach it securely to the bracket. The dryer requires 
two conductors for power plus a separate ground wire. 

6.

Attach the mechanism firmly to the wall. For wood walls or wood studs, use No. 16 screws of proper length 
to ensure 1” (25 mm) minimum stud penetration. For masonry walls use expansion bolts or anchors for 
1/4” (6 mm) screws of proper length to ensure penetration 1/4” (6 mm) deeper than anchor. Shim if 
necessary to ensure that the base plate is level and flat against the wall

.

 