PATLITE EHV User Manual

Horn type annunciator, Instruction manual, Type : ehv/ehs

Advertising
background image

Horn Type Annunciator

V95100151

4283-E

Instruction Manual

[ TYPE : EHV/EHS ]

Thank you for purchasing Patlite's horn type annunciator for your application. Prior to

installation, please read through this manual for proper installation and precautionary

steps. In addition, please store this manual for future reference when performing

maintenance, repairs or inspections. When performing maintenance and repairs, etc.,

please be sure to reread this book. In addition, if there are any questions concerning this

product, feel free to contact your PATLITE Sales Representative.

This book describes precautions of the product, as well as installation and wiring method, etc.

For further details, please visit the PATLITE homepage (http://www.patlite.com/) to download

the "Complete Operation Manual".

In order to prevent any damage to the user and other personnel or to assets, note the following:

The following symbols classifies the following precautions into two catagories and explains the

level of harm inflicted when caution is disregarded while using this product.

Displays the warning "Failure to follow warning may lead to death or severe

injury".
Displays the warning "Failure to follow caution may lead from light to medium

injury or maylead to property loss or injury to others".

WARNING

CAUTION

PLEASE

Indicates something to observe before using this product. The disregard to

this indication may lead to product malfunction or failure.

PLEASE

Prior to installation and wiring, ensure the power is disconnected and the Main Unit is

turned off. More important, perform proper insulation of the cabtyre cord connection when

using for outdoor applications. Failure to comply may result in electric shock or fire.

Be sure the wiring is correct. If an error is made in wiring, the internal circuit will be

damaged and may cause a fire.

Please be sure the power source is in the voltage tolerance when using it. Failure to

comply may result in malfunction or fire.

Do not disassemble or modify this product. Possibility of fire or electric shock may occur.

Refer to the "Troubleshooting" section, or ask for technical consultation from the addresses

indicated in this manual for repair, etc. of this product.

Request the installation and wiring be performed by a professional contractor. There is a

risk of an electric shock, fire, or falling.

Be sure to operate the product with the cover attached, and use the recommended torque.

Failure to comply can result in water and dust entering and causing product damage.

(Recommended Torque: 0.7 N

・m)

Do not install the product in a location where vibrations exceeding the specifications exist.

Failure to comply may result in the prevention of the product detaching and falling, causing

injury to a passer-by, etc.

Connect an external fuse between the power supply circuit and the Main Unit to protect the

internal circuitry.

Do not use in an environment exposed to strong radio waves or inductance noise. Failure

to comply will result in malfunction due to the influence of noise.

Do not use in an environment where corrosive gas is present. Possible cause of failure

may occur.

Discharge any static electricity from the body before handling static sensitive parts, such

as the SD Card. To prevent damage from static electricity, touch hands or other body parts

to metals or an earth ground to discharge the body from static charge.

Use the recommended torque when attaching parts for installation, etc.

Be sure not to lose parts for the cover, waterproofing ground, etc. when removing while

performing work on the product.

If this product is used for the purpose of preserving safety, please be sure to implement

daily inspections and include a back-up system design which can respond at the time of

emergency, in case any defect or failure may occur.

WARNING

CAUTION

Contrary to Warnings and Cautions indicated in this document, product failure due to mishandling,

disassembly, modifications or natural disasters, etc. is not covered by any Warranty. Moreover,

avoid any applications outside those indicated in this document.

1. For safe application, observe the following:

On-board Memory Size

2 MByte (including management domain)

32 kb/sec., 64 kb/sec. (Standard), 128 kb/sec.

Maximum Playback Time

Total of 220 sec. (at standard bit rate, one MP3 file)

Playback File

MPEG1-Audio Layer

Ⅲ (MP3)

MPEG Layer-3 audio coding technology licensed from Fraunhofer IIS and Thomson Licensing.

Available Bit Rates

Constant bit rate (CBR) Only

Remarks

Joint Stereo and Dual Channel not available.

-

※1

-

※1

※2

※2

FCC Part15 SubpartB Class A

-

EH□-M1

EH□-M2

EH□-M3

Conformity Standards

UL 464, CSA22.2 No. 205-M1983

-

-

KC (KN22, KN24)

ECE Regulation No. 10

※1 There are no contents of controlled substances exceeding the threshold for the RoHS Directive.
※2 UL Listed (File No.S24210)

-

EMC Directive (EN 61000-6-4, EN 61000-6-2)

EMC Directive (EN 13309)

RoHS Directive (EN 50581)

-

-

-

-

-

* The voltage contact input should be in the range of 10.8 V DC to 31.6 V DC.

* The voltage contact input should be in the range of 10.8 V DC to DC 31.6 V DC.

- Caution on copyright -

Work that was recorded or copied from music CDs or other media used in public places may

infringe upon copyrights and law enforcement may be imposed. When using a work that was

recorded or copied from music CDs or other media, be sure to obtain permission from the author.

In addition, copyright of audio/music data distributed or sold by the PATLITE Corporation belongs

to PATLITE. It is strictly prohibited to copy/reprint whole or partial contents of audio/music data

belonging to the PATLITE Corporation, or to transfer/sell such material on computer networks,

etc., without permission of the rightful holder.

Although copyright licensing in Japan for the EHS-

□□□ (Type A, C, D) and EHV-□□F□ (Type

F) has been obtained at PATLITE, since the copyright licensing of countries other than Japan is

not included, it is the responsibility of the customer to acquire permission, themselves.

However, since copyright consent is not necessary when using the required tones for the

EHS-

□□E (Type E) and EHV-□□G□ (Type G), it can be used for countries outside of Japan.

Voltage Contact (for EH□-M1)

Channel8 Blue
Channel7 Green
Channel6 Orange
Channel5 Red
Channel4 Light Green
Channel3 Pink
Channel2 Yellow
Channel1 Skyblue
COM Brown
Power White
Power Black

GND

Rated Voltage *

DC Power

PNP Transistor

Wire

Insulation

Fuse

Non-voltage Contact

Channel8 Blue
Channel7 Green
Channel6 Orange
Channel5 Red
Channel4 Light Green
Channel3 Pink
Channel2 Yellow
Channel1 Skyblue
COM Brown
Power White
Power Black

Fuse

GND

Rated Voltage

DC Power

AC Power

Rated Voltage

NPN Transistor

5. Wiring and Proper Use

3. Part Names

EHS Type

Rated Voltage

M1 : 12-24 V DC
M2 : 100-240 V AC (50/60Hz)
M3 : 12-48 V DC

EHS - M1HA

Connection Type

H : Cabtyre Cord
T : Terminal Buss(

※)

※EHS-M1 and EHS-M2 Only

Sound Type

A : Type A
C : Type C
D : Type D
E : Type E

Cover

Angle

Angle

Resin Washer

Angle-locking

M8 Bolt

* The PATLITE Corporation is a member
of the SD Card Association.

SD Card

Model: SDV-2GP

(Sold Separately)

* Please supply the bolts (M8) or screws

for the angle bracket installation from the

customer.

Waterproof

Packing

Volume

Mode Switch

M4 Screws

Case

When installing, fix the angle bracket with the proper bolts [ M8 ] in the three holes on the angle

bracket. (Fig. 1)

When using in a location with strong vibrations, it is recommended to use the recommended Vibration

Absorption Rubber. Affix the recommended Vibration Absorption Rubber in the two locations on the

angle bracket.(EH

□-M3 Only) (Fig. 1)

● Recommended Parts: Vibration Absorption Rubber KE-30 (Kurashiki Kako Co., Ltd.)(RoHS Compliant)

● The recommended Vibration Absorption Rubber is suitable for a vibration resistance of up to

70.0 m/s

2

(JIS D 1601-1995. Class 3 Class B).

Angle the case at a downward direction from the horizontal position and install it. Failure to do

so may result in water collecting, causing damage. (Fig. 2)

The angle adjustment bolt [ M8 ] is loosely tightened. Be sure to tighten when installing.

(Recommended Torque: 6.0 N

・m)

It is recommended for outdoor installation, to install under a roof with about a 45 degree angle

so that strong wind and rain water may not hit it directly. It is also recommended to add some

slack to the cabtyre cord and to insulate the sheath part of the cabtyre cord and wires to

waterproof them. Failure may result since water is suceptible to penetration through the cut

sections of the cabtyre cord. (Fig. 3)

(Fig. 2)

(Fig. 1)

(Fig. 3)

Example of water permeation prevention

to drain water away from the Main Unit.

Waterproof

Splicing

(Taping etc.)

Waterproof

Connection

(Taping etc.)

Facing

Upward

The power supply should be turned off prior to attachment at any cost. Failure to comply

may result in electric shock.

WARNING

PLEASE

If installed in a place where large vibrations are generated, screws and bolts should be

periodically tightened, and the product inspected.

Since the product may shake vigorously from heavy vibration, when attaching rubber

cushions, ensure sufficient space is available to avoid the product from colliding with

surrounding obstacles. (EH

□-M3 Only)

When installing in high places, choose a location which is accessible by a scaffold, ladder,

etc., for repairs.

A resin washer is recommended for use with the Angle Bracket.

It is recommended to locate a switch near the product, if it is connected directly to the power

supply, for safety in case the power supply has to be cut immediately.

Install the product in a location where the cover can be removed for maintenance or setup of

message contents, etc.

Facing
Downward

Angle the case at a downward direction from the horizontal position and install it. Failure to

do so may result in water collecting, causing damage.

The clamping surface should be sufficient enough to tolerate the weight of the product. Do

not use the product in a place where vibrations exceeds the specifications. Failure to

comply may result in the prevention of the product detaching and falling, causing injury to a

passer-by, etc.

Be sure to attach the angle fixed bolt [ M8 ] with the recommended torque. Failure to comply

may result in the prevention of the product detaching and falling, causing injury to a

passer-by, etc. Failure to comply may result in the prevention of the product detaching and

falling, causing injury to a passer-by, etc. (Recommended Torque: 6.0 N

・m)

Be sure to attach the rubber cushions to the angle bracket with the recommended torque

value. (Recommended Torque: 12.0 N

・m) (EH□-M3 Only)

It is recommended to periodically replace the Vibration Absorption Rubber. The rubber can

deteriorate and may cause a risk for injury due to the product falling and breaking.

(EH

□-M3 Only)

CAUTION

4. Installation

EH□-M2

EH□-M3

5.1 W (at 48 V DC)

Max : 110 dB (Directly in front at 1m from horn, alarm Stutter (rapid intermittent

EH□-M1

Playback Channel Inputs

Bit : 8 / Binary : 63

Bit : 8 / Binary : 32

Playback Delay Time

300 ms or less (At Signal / Power Input)

5.0 W (Non-voltage contact ・ NPN, at 12 V DC)

6.9 W (at 240 V AC)

EHS

5.6 W (at 48 V DC)

4.0 W (Non-voltage contact ・ NPN, at 12 V DC)

5.3 W (at 240 V AC)

EHV

Alarm

Condition

Playback Sound

MP3 Data / Alarm / Melody (Standard)

Alarm / Melody (Standard)

Rated Power
Consumption

Standard

Maximum Volume with -6 dB 1 kHz sound) Maximum Volume with "Rapid Hi-Lo" sound playback

Model

Sound

Pressure

Level

MP3

Max : 105 dB (Directly in front at 1m

and -6 dB 1 kHz sound playback)

5.0 W (Voltage contact ・ PNP, at 24 V DC)

5.9 W (Voltage contact ・ PNP, at 24 V DC)

Vibration Resistance

Recommended Parts: Vibration Absorption Rubber KE-30 (Kurashiki Kako Co., Ltd.)(RoHS Compliant)

45.0 m/s

2

IEC 60068-2-6:2007

70.0 m/s

2

JIS D 1601-1995 Class 3 Class B

(It is recommended only for the EH□-M3 to attach in the upright position when using the Vibration Absorption Rubber)

Voltage applied between terminal and chassis without breaking insulation.

500 V AC for 1 min.

1500 V AC for 1 min.

1000 V AC for 1 min.

Supported Memory Card

SD Card, SDHC Card

Recommended SD Card: SDV-2GP (Option)

File Format

FAT16, 32

Volume Adjustment

Volume adjustable from minimum to maximum

Sound reduction input to reduce from current level (depending on settings)

Mass (Tolerance ±10%)

1.25 kg

Impact Resistance

250m/s

2

6ms 1000times (one direction each of 3 axis)

、500m/s

2

11ms 3times (both directions each of 3 axis)

IEC 60068-2-27:2008

Withstand Voltage

Indoor / Outdoor

Upright, Sideways, Inverted (Case is to be pointed in downward direction)

Mounting

Condition

Upright Position

Insulation Resistance

More than 1MΩ at 500V DC between terminal and chassis

Location

Position

90-264 V AC 50/60Hz

10-60 V DC

Protection Rating

IP65 (IEC 60529)

Operating Ambient Humidity

85 % or less RH (no condensation)

Storage Ambient

-30℃ to 60℃

Storage Ambient Humidity

85 % or less RH (no condensation)

Operating Ambient

-20℃ to 50℃

EH□-M2

EH□-M3

Rated Voltage

12-24 V DC

100-240 V AC 50/60Hz

12-48 V DC

Operating Voltage Range

10.8-3.5 V DC

Model

EH□-M1

Rated Voltage

(Fuse withstand voltage)

Rated Current

(Fuse capacity)

Fusing Type

250 V
250 V

800 mA

Table 3: Inrush Current

EH

□-M1

EH

□-M2

EH

□-M3

Normal Blow, PSE Class A

250 V

500 mA

800 mA

Normal Blow, PSE Class A

Normal Blow, PSE Class A

12.5 A

Current value

23 A
45 A

Current Capacity

Table 1: Signal Contact Capacity

Withstand Voltage

10 mA or more

10 mA or more

15 mA or more

Applied Voltage : 26.4 V DC or more

Applied Voltage : less than 26.4 V DC

Non-Voltage Contact

Voltage Contact (for EH□

-M1)

35 V DC or more

Leakage Current

ON Voltage(Vsat)

0.1 mA or less

1 V or less

Table 2: Recommended Fuse

Wiring Example (Cabtyre Cord Type)

Wiring Example (Terminal Buss Type)

The following are recommended specifications when connecting a cabtyre cord to a terminal buss:

● Diameter: φ8.5mm to φ10.5mm.
● Terminal: M3 insulated O-ring crimping connector corresponding to the RoHS directive.

● Be sure wiring is carried out correctly. Failure to conform may result in product damage,

resulting in damage to the circuitry or fire.

● Wiring should be done after the power supply is turned off. Failure to comply may result in

electric shock.

● When using a terminal buss model, ensure the terminal screws are tightened with the

recommended torque value when wiring. Failure to comply may result in wires coming loose

from vibration and causing shorting between wires, causing posible malfunction or even

electric shock.(Recommended Torque: 0.3 N

・m)

WARNING

Be sure to operate the product with the cover attached, and use the recommended torque.

Failure to comply can result in water and dust entering and causing product damage.

(Recommended Torque: 0.7 N

・m)

If the product is used in an environment with a lot of water or dust, it is recommended to use

a 8.5 to 10.5mm cabtyre cord with a waterproof gland. The protection rating value cannot be

assured in such environments, and a risk of failure may occur.

CAUTION

PLEASE

Connect an external fuse between the product and power supply to protect the internal

circuitry.

Be sure to check for proper wiring before connecting the power.

To countermeasure against noise, shorten the wiring as much as possible, and it is

recommended to use shielded wire. In addition, separate any signal lines which pass along

high voltage cables or is susceptible to receive induction noises.

Any of the unused wires for the cabtyre cord should be individually insulated after wiring.

Failure to comply may result in malfunction.

If a non-voltage contact, such as a relay or switch etc., is used for the power supply line,

consider inrush current capacity when selecting the contact. If inrush capacity runs

insufficient, it will result in contact arcing and malfunction.

If this product is used in conjunction with our products other than EHV/EHS, the signal and

COM lines are not to be connected together. (Since there is a voltage potential between the

signal lines, the circuitry may become damaged.) Be sure to use a switch or relay to divide

the two circuits at the point of contact.

Use the same power source as the product when applying voltage to a voltage-contact

signal line.Applying a voltage outside the power source used for the product may result in

malfunction or damage to the product. (EH

□-M1 Only)

Please use contacts, such as relay switchs or transistor circuits (NPN/PNP type) for

external contacts. Refer to Tables 1 to 3 for Contact Capacity values.

Please understand that responsibility cannot be taken by PATLITE from failure, damage, etc., which

was generated by user's mishandling in contrary to the warnings and precautions written in this book.

Due to changes, improvements, etc., the contents of this manual may change without advance notice.

EH

□-M1

EH

□-M2

EH

□-M3

Waterproof Cap

Waterproof Gland

Cabtyre Cord

(For Cabtyre Cord Type)

A

A

Inside Cover

SD

Card

Vibration

Absorption Rubber

EHV Type

Rated Voltage

M1 : 12-24 V DC
M2 : 100-240 V AC (50/60Hz)
M3 : 12-48 V DC

EHV - M1HFM

Connection Type

H : Cabtyre Cord
T : Terminal Buss(

※)

※EHV-M1 and EHV-M2 Only

Sound Type

F : Type F
G : Type G

Message Type

Blank : None
M : Pre-recorded

Voltage Contact (for EH□-M1)

DC Power

Fuse

Rated Voltage *

GND

PNP Transistor

Non-voltage Contact

NPN Transistor

AC Power

Rated Voltage

GND

DC Power

Rated Voltage

Fuse

2. Model Number Configuration

Safety Precautions

The following table corresponds to the factory-set message registration contents at the

time of shipment for this machine.

For more details regarding the various setups, visit the PATLITE homepage

(http://www.patlite.com/) to download the "Complete Operation Manual".

Model

Channel Input Method

Playback Mode

MP3 Setup

Bit

Bit

Bit

Binary

Normal

Up to No. 8 No. 9 or more

ON

OFF

EHS-

□□□

EHV-

□□□

M

EHV-

□□□

Ch Msg. No.

6. Factory Settings

7-1 Standard Specifications

7-3 Model Specifications

7-4

Conformity Standards

7-2 MP3 Specifications (EHV)

7-5 Outer Dimensions (mm)

7. Specifications

This device complies with part 15 of the FCC Rules.

Operation is subject to the following two conditions:

(1) This device may not cause harmful interference.

(2) This device must accept any interference received, including interference that may cause

undersired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device,

pursuant to part 15 of the FCC Rules.

These limits are designed to provide reasonable protection against harmful interference when the

equipment is operated in a commercial environment.

This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used

in accordance with the instruction manual, may cause harmful interference to radio communications.

Operation of this equipment in a residential area is likely to cause harmful interference in which case

the user will be required to correct the interference at his own expense.

NOTE

'13.9.AUTO

4283-E

Advertising