5.3.3 MAM Axes Select Byte

The MAM Axes Select Byte establishes which axes are to be measured and is defined as

follows:

Bit #

7

6

5

4

3

2

1

0

Value

0

0

0

AAX1 AAX0

0

0

1

Table 5-3: MAM Axes Select Bits

Axes to be Measured

AAX1

AAX0

X, Y, and Z

0

0

X and Y

0

1

X only

1

0

No axis measured

1

1

5.3.4 Making a Multi-Axis Measurement

The steps to make a multi-axis sensor measurement are given below. The RM3000

Evaluation Board will return the result of a complete forward- reverse measurement of

each sensor in a 24 bit 2’s complement format (range: -8388608 to 8388607).

Start with SSN set HIGH, then set SSN to LOW.

Initiate a sensor measurement by sending 82

H

(MAM Command Byte to write to

the Mode Register) followed by 01

H

(Mode Register Word to initiate

measurement) on the MOSI pin. The RM3000 Evaluation Board will now take

the prescribed measurements.

Return SSN to HIGH. This will not affect the measurement process, but will free

up the host to communicate with other devices and ensure the next Command

Byte sent to the module is interpreted properly.

A measurement is taken.

At the end of the measurement, the DRDY pin is set HIGH, indicating data is

ready, and the RM3000 Evaluation Board is placed in Idle Mode.

When the host is ready to read the measured values, set SSN to LOW. If SSN

already is LOW, then toggle SSN from LOW to HIGH to LOW.