Maintenance

Service Schedule

Engine

Daily

Check engine oil level. *** Fill to proper level (Do not overfill)

Vacuum Pump

Daily

Spray water displacing lubricant in lubrication cup at front of
console for 5 sec.

Solution Pump

Daily

Check oil level.** Fill to proper level (Do not overfill)

Chemical Inlet Tube Strainer

Daily

Check strainer for blockage, remove any debris

Vacuum Inlet Filter (In Waste Tank)

Daily

Clean filter, inspect, replace if damaged

Vacuum Hoses

Daily

Wash out with clean water

Automatic Waste Pump

Daily

Inspect and remove any debris or sediment

Vacuum Pump

Weekly*

Check oil level. Fill to proper level

Water Box Float Valve

Weekly

Check for proper seating and shut-off

Solution Pump Inlet Strainer

Weekly*

Check for debris and clean

Temperature Balance Orifice

Weekly

Remove, clean and check screen (as needed)

Battery

Weekly*

Check for proper fluid level. Fill with distilled water only

Solution Outlet Screen

Weekly*

Inspect and remove any debris or blockage

High Pressure Hoses

25 hrs

Inspect for damage or impending damage

Pressure Regulator

50 hrs

Lubricate o-rings

Pressure Regulator

50 hrs

Lubricate plug behind spring

Engine

100 hrs

Change engine oil and oil filter***

Battery

100 hrs*

Clean battery terminals

Automatic Waste Pumpout

100 hrs

Clean inlet and outlet ports

Belts/Pulleys

100 hrs

Check belt wear and tension. Check pulley alignment.

Water Box Float Valve Seal

200 hrs.

Inspect and replace seal as needed

Engine

200 hrs

Service air cleaner elements*

Fuel Pump

200 hrs

Check hose connections

Engine

200 hrs

Replace fuel filter (carbureted engines)

Engine

200 hrs

Check spark plugs for carbon deposits and proper gap

Chemical Valves

200 hrs

Inspect and/or adjust packing nuts

Temperature Control Valve

200 hrs

Inspect and/or adjust packing nuts

86313050 LEGEND GT