400-276-002-C 17/1/07 1/2

The RC840T Electric Heating Relay is designed to control a line
voltage resistive load from a low voltage thermostat. The RC840T
relay has a built-in 24 V transformer and is compatible with 3-wire
(R,C,W) thermostats as well as 2-wire mechanical and battery-
operated thermostats.
The RC840T operates silently and can be installed in bedrooms,
living rooms, or any other occupied area without disturbing
occupants. On a call for heat, the relay is immediately activated;
there is no delay. This increases temperature control and comfort.

NOTE:

Not recommended for fast-cycling modulated regulation. For

fast-cycling heating equipment, It is recommended to use the RT850
or RT850T (integrated 24 V transformer) Solid State Relay.

I

The RC840T must be installed in an area where the temperature is
between -4°F and 140°F (-20°C and 60°C).
The RC840T can be installed on the side of an electrical box or a
distribution panel or inside the wiring compartment of an electric
baseboard.



All wiring must comply with national and local electrical
code regulations.



Installation should be carried out by an electrician.



Disconnect power supply before installing the relay to
prevent electrical shock.

n

Secure relay to the mounting surface using the two mounting
brackets. Use the supplied lock nut to secure the relay to the
junction box.

o

Wire the relay and connect according to typical wiring diagrams
(refer to figures 1 & 2).

p

Once mounting and wiring have been completed, return power
to the heating system and test the installation.

q

Increase the thermostat temperature to activate the relay. Allow
system operation long enough to proof installation. Once
installation has been proofed, set temperature to normal
setpoint.

Figure 1 :

Connection to a 2-wire low voltage thermostat

Figure 2 :

Connection to a 3-wire low voltage thermostat

n

Application

1.

o

Installation

2.

O

n the side of

an electrical box

I

nside the wiring compartment

of a baseboard

For proper installation, use
a screw and a washer.

p

Typical Wiring Diagrams

3.

You must provide an overload protection and
disconnect as required.

Low-voltage
2-wire
thermostat

Junction box

Load

Black

Red

Blue

You must provide an overload protection and
disconnect as required.

Low-voltage
3-wire
thermostat

Junction box

Load

Red

Blue

Black

RC840T

Installation Guide

On/Off Switching Electric Heating Relay with Built-in 24 V Transformer

400-276-002-C (RC840T) ENG.fm Page 1 Wednesday, January 17, 2007 3:47 PM

Advertising