GENERAL SPECIFICATIONS

AC Receptacle:

2 – Dual Three-prong

Battery Polarity Protect:

Yes (Fuse)

DC Fuse (Recommended):

70 A

Dimension (L x W x H):

13 x 6.25 x 3.75

Efficiency:

88%

Output Short Protect:

Yes (Button Breaker)

Output Waveform:

Pure Sine Wave (<3% Thd)

Operating Temperature Range:

32

° F – 158° F (0° Fc – 40° C)

Overload Protect:

Yes

Storage Temperature Range:

-22

° F - 158° F (-30° C – 70° C)

Part Number:

79400 With Outlets

Part Number:

79405 Hardwired

Thermal Protect:

50 +/-5 Deg C

Weight:

13 Lbs

ELECTRICAL SPECIFICATIONS

Battery Low Shutdown:

10.5 VDC

Continue Output Power:

400 W

Input Voltage Range:

10.5 – 15.3 VDC

Input Full Load Current:

40 A

No Load Power Draw

0.5 A

Output Frequency:

60 +/- 0.05 Hz

Output Power:

400 Watts

Output Voltage (At No Load):

120 Vac Rms +/- 3 V

Output Voltage (At Full Load):

120 Vac Rms +/- 5 V

Peak Output Power:

1000 Va Surge For 5 Seconds

CAUTION:

ALWAYS PLACE THE INVERTER IN AN ENVIRONMENT WHICH IS:

(A)

WELL VENTILATED

(B)

NOT EXPOSED TO DIRECT SUNLIGHT OR HEAT SOURCE

(C)

OUT OF REACH FROM CHILDREN

(D)

AWAY FROM WATER / MOISTURE, OIL OR GREASE

(E)

AWAY FROM ANY FLAMMABLE SUBSTANCE

4

TRUEPOWER 400PS FEATURES

1. ON / Off Switch

turns the inverter to ON or to OFF.

2. Shore Power light

illuminates when you are connected to shorepower. (shorepower

refers to the AC input power from a utility grid, generator or external AC source)
3. Inverter / Fault Light

illuminates Green when the inverter is operating and

illuminates Red for fault conditions such as over temperature, output overload,
or battery over voltage.
4. Two AC Outputs

to power connected appliances.

5. Supplemental Circuit Protection Button

may trip if there is an over-current (over

10 amps) or a short circuit.
6. GFCI

opening enables the Reset and Test monthly capabilities.

7. Fan

(internal) activates when the internal temperature of the inverter increases.

The fan speed varies with the internal temperature and turns off when the inverter
cools down.

1. DC Input Cables
2. AC Receptacles
3. AC Input cord for shorepower
4. Wiring box access panel

(Top panel)

5. AC Strain Relief

for hardwiring

6. Chassis ground lug
7. Remote control jack
8. Mounting flanges

(Side panel)

9. Ventilation openings

provides

air circulation (Side panel)

T r u e P o w e r 4 0 0 P S F e a t u r e s

S p e c i f i c a t i o n s

15

Figure 2

9

8

4

6

7

1

2

3

5

Remote

DC Grounding

Connector

AC Output

AC Input

DC Input

Figure 1

6

7

5

4

3

2

1

RESET

RESET

TEST

TEST

Shore ON

Red: Inverter Fault

Green: Inverter ON

POWER STATUS

POWER

AC SHORE
BREAKER

Advertising